{"title":"Best Sellers","description":"","products":[{"product_id":"s-type-dental-implant-internal-hex-2-43","title":"S-Type Dental Implant","description":"\u003cp\u003eThe \u003cstrong data-start=\"498\" data-end=\"515\"\u003eSurcam S-Type\u003c\/strong\u003e is a parallel-body, spiral implant engineered for reliable primary stability across bone densities. The \u003cstrong data-start=\"620\" data-end=\"662\"\u003eself-drilling\/self-tapping macrodesign\u003c\/strong\u003e and \u003cstrong data-start=\"667\" data-end=\"683\"\u003econical core\u003c\/strong\u003e promote controlled insertion, while \u003cstrong data-start=\"720\" data-end=\"748\"\u003econtinuous micro-threads\u003c\/strong\u003e at the crestal zone help modulate cervical stress and support micro-circulation. An \u003cstrong data-start=\"833\" data-end=\"851\"\u003eanchoring apex\u003c\/strong\u003e aids trajectory control—especially useful in dense bone—while the proven \u003cstrong data-start=\"925\" data-end=\"972\"\u003eSLA (sand-blast + double acid-etch) surface\u003c\/strong\u003e supports rapid, predictable bone contact.\u003cbr data-start=\"1014\" data-end=\"1017\"\u003e\u003cstrong data-start=\"1017\" data-end=\"1043\"\u003eConnection \/ Platform:\u003c\/strong\u003e \u003cstrong data-start=\"1044\" data-end=\"1068\"\u003eInternal Hex 2.43 mm\u003c\/strong\u003e (verify interface and system compatibility). Select diameter\/length based on anatomy, bone density, and restorative plan per IFU.\u003c\/p\u003e\n\u003ch2 data-start=\"3057\" data-end=\"3064\"\u003eFAQs\u003c\/h2\u003e\n\u003ch3 data-start=\"3066\" data-end=\"3114\"\u003eWhich systems is the S-Type compatible with?\u003c\/h3\u003e\n\u003cp data-start=\"3115\" data-end=\"3232\"\u003eDesigned for \u003cstrong data-start=\"3128\" data-end=\"3152\"\u003eInternal Hex 2.43 mm\u003c\/strong\u003e platforms. Always \u003cstrong data-start=\"3171\" data-end=\"3195\"\u003everify interface\/fit\u003c\/strong\u003e with your implant system before use.\u003c\/p\u003e\n\u003ch3 data-start=\"3234\" data-end=\"3274\"\u003eHow do I choose diameter and length?\u003c\/h3\u003e\n\u003cp data-start=\"3275\" data-end=\"3457\"\u003eBase selection on \u003cstrong data-start=\"3293\" data-end=\"3356\"\u003ebone volume\/density, available height, and restorative plan\u003c\/strong\u003e per your surgical protocol\/IFU. Wider diameters can increase primary stability when anatomy permits.\u003c\/p\u003e\n\u003ch3 data-start=\"3459\" data-end=\"3509\"\u003eIs the implant self-drilling and self-tapping?\u003c\/h3\u003e\n\u003cp data-start=\"3510\" data-end=\"3682\"\u003eYes. The \u003cstrong data-start=\"3519\" data-end=\"3544\"\u003espiral, coarse-thread\u003c\/strong\u003e design with a \u003cstrong data-start=\"3559\" data-end=\"3575\"\u003econical core\u003c\/strong\u003e supports self-drilling\/self-tapping insertion. Follow the manufacturer’s \u003cstrong data-start=\"3649\" data-end=\"3670\"\u003edrilling sequence\u003c\/strong\u003e in the IFU.\u003c\/p\u003e\n\u003ch3 data-start=\"3684\" data-end=\"3732\"\u003eCan I use it for immediate or early loading?\u003c\/h3\u003e\n\u003cp data-start=\"3733\" data-end=\"3862\"\u003e\u003cstrong data-start=\"3733\" data-end=\"3803\"\u003eOnly when primary stability and occlusal control meet IFU criteria\u003c\/strong\u003e (e.g., adequate torque\/ISQ and splinting where indicated).\u003c\/p\u003e\n\u003ch3 data-start=\"3864\" data-end=\"3902\"\u003eWhat does the SLA surface provide?\u003c\/h3\u003e\n\u003cp data-start=\"3903\" data-end=\"4047\"\u003eThe \u003cstrong data-start=\"3907\" data-end=\"3922\"\u003eSLA surface\u003c\/strong\u003e (sand-blast + double acid etch) is designed to enhance \u003cstrong data-start=\"3978\" data-end=\"4005\"\u003ebone-to-implant contact\u003c\/strong\u003e and support predictable osseointegration.\u003c\/p\u003e","brand":"Surcam","offers":[{"title":"Ø3.3 \/ 8.0 mm","offer_id":39896966266945,"sku":"S33008INX","price":70.0,"currency_code":"USD","in_stock":true},{"title":"Ø3.3 \/ 10.0 mm","offer_id":40047870640193,"sku":"S33010INX","price":70.0,"currency_code":"USD","in_stock":true},{"title":"Ø3.3 \/ 11.5 mm","offer_id":40047870672961,"sku":"S330115INX","price":70.0,"currency_code":"USD","in_stock":true},{"title":"Ø3.3 \/ 13.0 mm","offer_id":40047870738497,"sku":"S33013INX","price":70.0,"currency_code":"USD","in_stock":true},{"title":"Ø3.75 \/ 8.0 mm","offer_id":39896967905345,"sku":"S37508INX","price":70.0,"currency_code":"USD","in_stock":true},{"title":"Ø3.75 \/ 10.0 mm","offer_id":40047870804033,"sku":"S37510INX","price":70.0,"currency_code":"USD","in_stock":true},{"title":"Ø3.75 \/ 11.5 mm","offer_id":40047870836801,"sku":"S375115INX","price":70.0,"currency_code":"USD","in_stock":true},{"title":"Ø3.75 \/ 13.0 mm","offer_id":40047870869569,"sku":"S37513INX","price":70.0,"currency_code":"USD","in_stock":true},{"title":"Ø3.75 \/ 16.0 mm","offer_id":40047870902337,"sku":"S37516INX","price":70.0,"currency_code":"USD","in_stock":true},{"title":"Ø4.2 \/ 8.0 mm","offer_id":39896968069185,"sku":"S42008INX","price":70.0,"currency_code":"USD","in_stock":true},{"title":"Ø4.2 \/ 10.0 mm","offer_id":40047870935105,"sku":"S42010INX","price":70.0,"currency_code":"USD","in_stock":true},{"title":"Ø4.2 \/ 11.5 mm","offer_id":40047870967873,"sku":"S420115INX","price":70.0,"currency_code":"USD","in_stock":true},{"title":"Ø4.2 \/ 13.0 mm","offer_id":40047871000641,"sku":"S42013INX","price":70.0,"currency_code":"USD","in_stock":true},{"title":"Ø4.2 \/ 16.0 mm","offer_id":40047871033409,"sku":"S42016INX","price":70.0,"currency_code":"USD","in_stock":true},{"title":"Ø5.0 \/ 8.0 mm","offer_id":39896968233025,"sku":"S50008INX","price":70.0,"currency_code":"USD","in_stock":true},{"title":"Ø5.0 \/ 10.0 mm","offer_id":40047871066177,"sku":"S50010INX","price":70.0,"currency_code":"USD","in_stock":true},{"title":"Ø5.0 \/ 11.5 mm","offer_id":40047871098945,"sku":"S500115INX","price":70.0,"currency_code":"USD","in_stock":true},{"title":"Ø5.0 \/ 13.0 mm","offer_id":40047871131713,"sku":"S50013INX","price":70.0,"currency_code":"USD","in_stock":true},{"title":"Ø5.0 \/ 16.0 mm","offer_id":40047871164481,"sku":"S50016INX","price":70.0,"currency_code":"USD","in_stock":true},{"title":"Ø3.75 \/ 18.0 mm","offer_id":44448680837185,"sku":"S33008INX-2","price":70.0,"currency_code":"USD","in_stock":true},{"title":"Ø4.2 \/ 18.0 mm","offer_id":44448680869953,"sku":"S33008INX-3","price":70.0,"currency_code":"USD","in_stock":true},{"title":"Ø5.0 \/ 18.0 mm","offer_id":44448680902721,"sku":"S33008INX-4","price":70.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0558\/0180\/6913\/products\/s-type_dental_implant_internal_hex_2.43_spiral_self-tapping_sla.jpg?v=1758008923"},{"product_id":"straight-multi-unit-abutment-prime-coating","title":"Straight Multi-Unit Abutment – Prime Coating","description":"\u003cp data-start=\"423\" data-end=\"799\"\u003eThe \u003cstrong data-start=\"427\" data-end=\"475\"\u003eStraight Multi-Unit Abutment – Prime Coating\u003c\/strong\u003e is designed to support predictable screw-retained implant restorations while providing stable prosthetic alignment and improved restorative access. Manufactured from \u003cstrong data-start=\"642\" data-end=\"674\"\u003eTitanium Grade 5 (Ti-6Al-4V)\u003c\/strong\u003e, it delivers excellent mechanical strength, corrosion resistance, and long-term durability in demanding clinical conditions.\u003c\/p\u003e\n\u003cp data-start=\"801\" data-end=\"1055\"\u003eThe abutment features \u003cstrong data-start=\"823\" data-end=\"851\"\u003eSurcam Prime PVD coating\u003c\/strong\u003e, enhancing surface hardness and wear resistance while maintaining precise prosthetic interface integrity. This advanced coating improves durability and supports reliable long-term prosthetic performance.\u003c\/p\u003e\n\u003cp data-start=\"1057\" data-end=\"1367\"\u003eThe \u003cstrong data-start=\"1061\" data-end=\"1087\"\u003estraight configuration\u003c\/strong\u003e allows direct restorative access and optimal prosthetic positioning when implant angulation is favorable. Available in \u003cstrong data-start=\"1207\" data-end=\"1254\"\u003egingival heights of 1, 2, 3, 4, 5, and 6 mm\u003c\/strong\u003e, it enables clinicians to manage soft-tissue depth and create an ideal emergence profile for final restorations.\u003c\/p\u003e\n\u003cp data-start=\"1369\" data-end=\"1567\"\u003eDesigned for compatibility with \u003cstrong data-start=\"1401\" data-end=\"1433\"\u003einternal hex implant systems\u003c\/strong\u003e, the Straight Multi-Unit Abutment integrates seamlessly into modern implant prosthetic workflows and full-arch restoration protocols.\u003c\/p\u003e\n\u003cul data-start=\"1593\" data-end=\"2115\"\u003e\n\u003cli data-start=\"1593\" data-end=\"1661\"\u003e\n\u003cp data-start=\"1595\" data-end=\"1661\"\u003eStraight \u003cstrong data-start=\"1604\" data-end=\"1627\"\u003emulti-unit abutment\u003c\/strong\u003e for screw-retained restorations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1662\" data-end=\"1731\"\u003e\n\u003cp data-start=\"1664\" data-end=\"1731\"\u003e\u003cstrong data-start=\"1664\" data-end=\"1685\"\u003ePrime PVD coating\u003c\/strong\u003e for enhanced durability and wear resistance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1732\" data-end=\"1786\"\u003e\n\u003cp data-start=\"1734\" data-end=\"1786\"\u003eManufactured from \u003cstrong data-start=\"1752\" data-end=\"1784\"\u003eTitanium Grade 5 (Ti-6Al-4V)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1787\" data-end=\"1819\"\u003e\n\u003cp data-start=\"1789\" data-end=\"1819\"\u003eConnection: \u003cstrong data-start=\"1801\" data-end=\"1817\"\u003eInternal Hex\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1820\" data-end=\"1880\"\u003e\n\u003cp data-start=\"1822\" data-end=\"1880\"\u003eGingival heights available: \u003cstrong data-start=\"1850\" data-end=\"1878\"\u003e1 \/ 2 \/ 3 \/ 4 \/ 5 \/ 6 mm\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1881\" data-end=\"1932\"\u003e\n\u003cp data-start=\"1883\" data-end=\"1932\"\u003eDesigned for predictable prosthetic positioning\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1933\" data-end=\"1998\"\u003e\n\u003cp data-start=\"1935\" data-end=\"1998\"\u003eSupports optimal soft-tissue management and emergence profile\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1999\" data-end=\"2062\"\u003e\n\u003cp data-start=\"2001\" data-end=\"2062\"\u003eSuitable for single-unit and full-arch implant restorations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2063\" data-end=\"2115\"\u003e\n\u003cp data-start=\"2065\" data-end=\"2115\"\u003ePrecision-machined for stable implant connection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Surcam","offers":[{"title":"1.0 mm","offer_id":39896960335937,"sku":"EMU-0011","price":40.0,"currency_code":"USD","in_stock":true},{"title":"2.0 mm","offer_id":39896960368705,"sku":"EMU-0021","price":40.0,"currency_code":"USD","in_stock":true},{"title":"3.0 mm","offer_id":39896960401473,"sku":"EMU-0031","price":40.0,"currency_code":"USD","in_stock":true},{"title":"4.0 mm","offer_id":39896960434241,"sku":"EMU-0041","price":40.0,"currency_code":"USD","in_stock":true},{"title":"5.0 mm","offer_id":39896960467009,"sku":"EMU-0051","price":40.0,"currency_code":"USD","in_stock":true},{"title":"6.0 mm","offer_id":39896960499777,"sku":"EMU-0061","price":40.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0558\/0180\/6913\/files\/straight_multi_unit_abutment_prime_coating_internal_hex_2.42.png?v=1758446866"},{"product_id":"angular-multi-unit-abutment-3-75-prime-coating","title":"Angular Multi-Unit Abutment – Ø3.75 Standard Platform","description":"\u003cp data-start=\"416\" data-end=\"776\"\u003eThe \u003cstrong data-start=\"420\" data-end=\"467\"\u003eAngular Multi-Unit Abutment – Prime Coating\u003c\/strong\u003e is designed to correct implant angulation and provide an optimal prosthetic path for screw-retained implant restorations. Compatible with \u003cstrong data-start=\"606\" data-end=\"662\"\u003eØ3.75 standard platform internal hex implant systems\u003c\/strong\u003e, it enables clinicians to compensate for tilted implant placement while maintaining proper restorative alignment.\u003c\/p\u003e\n\u003cp data-start=\"778\" data-end=\"1059\"\u003eThe abutment is available in \u003cstrong data-start=\"807\" data-end=\"847\"\u003e18°, 30°, and 45° angulation options\u003c\/strong\u003e, allowing effective correction of implant trajectories in full-arch and complex restorative cases. This improves prosthetic access and helps achieve a parallel restorative platform for screw-retained prostheses.\u003c\/p\u003e\n\u003cp data-start=\"1061\" data-end=\"1373\"\u003eManufactured from \u003cstrong data-start=\"1079\" data-end=\"1111\"\u003eTitanium Grade 5 (Ti-6Al-4V)\u003c\/strong\u003e and enhanced with \u003cstrong data-start=\"1130\" data-end=\"1151\"\u003ePrime PVD coating\u003c\/strong\u003e, the abutment provides exceptional durability, wear resistance, and long-term mechanical stability. The coating improves surface hardness and helps maintain precise prosthetic interface integrity under functional loading.\u003c\/p\u003e\n\u003cp data-start=\"1375\" data-end=\"1576\"\u003eAvailable in \u003cstrong data-start=\"1388\" data-end=\"1447\"\u003egingival heights of 2.0, 3.0, 4.0, 4.5, 5.0, and 6.0 mm\u003c\/strong\u003e, the abutment allows clinicians to manage soft-tissue depth and create an optimal emergence profile for prosthetic restorations.\u003c\/p\u003e\n\u003cp data-start=\"1578\" data-end=\"1730\"\u003eDesigned for predictable implant prosthetic workflows, the Angular Multi-Unit Abutment integrates seamlessly into modern multi-unit restorative systems.\u003c\/p\u003e\n\u003cul data-start=\"1756\" data-end=\"2250\"\u003e\n\u003cli data-start=\"1756\" data-end=\"1821\"\u003e\n\u003cp data-start=\"1758\" data-end=\"1821\"\u003eAngular \u003cstrong data-start=\"1766\" data-end=\"1819\"\u003emulti-unit abutment for tilted implant correction\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1822\" data-end=\"1863\"\u003e\n\u003cp data-start=\"1824\" data-end=\"1863\"\u003ePlatform: \u003cstrong data-start=\"1834\" data-end=\"1861\"\u003eØ3.75 Standard Platform\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1864\" data-end=\"1896\"\u003e\n\u003cp data-start=\"1866\" data-end=\"1896\"\u003eConnection: \u003cstrong data-start=\"1878\" data-end=\"1894\"\u003eInternal Hex\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1897\" data-end=\"1936\"\u003e\n\u003cp data-start=\"1899\" data-end=\"1936\"\u003eAngles available: \u003cstrong data-start=\"1917\" data-end=\"1934\"\u003e18°, 30°, 45°\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1937\" data-end=\"1989\"\u003e\n\u003cp data-start=\"1939\" data-end=\"1989\"\u003eGingival heights: \u003cstrong data-start=\"1957\" data-end=\"1987\"\u003e2 \/ 3 \/ 4 \/ 4.5 \/ 5 \/ 6 mm\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1990\" data-end=\"2059\"\u003e\n\u003cp data-start=\"1992\" data-end=\"2059\"\u003e\u003cstrong data-start=\"1992\" data-end=\"2013\"\u003ePrime PVD coating\u003c\/strong\u003e for enhanced durability and wear resistance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2060\" data-end=\"2114\"\u003e\n\u003cp data-start=\"2062\" data-end=\"2114\"\u003eManufactured from \u003cstrong data-start=\"2080\" data-end=\"2112\"\u003eTitanium Grade 5 (Ti-6Al-4V)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2115\" data-end=\"2179\"\u003e\n\u003cp data-start=\"2117\" data-end=\"2179\"\u003eEnables parallel prosthetic platform in angled implant cases\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2180\" data-end=\"2250\"\u003e\n\u003cp data-start=\"2182\" data-end=\"2250\"\u003eSuitable for screw-retained restorations and full-arch prosthetics\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Surcam","offers":[{"title":"18° Deg \/ 2.0 mm","offer_id":40071915798593,"sku":"AMU-1801","price":55.0,"currency_code":"USD","in_stock":true},{"title":"18° Deg \/ 3.0 mm","offer_id":40071915831361,"sku":"AMU-1811","price":55.0,"currency_code":"USD","in_stock":true},{"title":"18° Deg \/ 4.0 mm","offer_id":40071915864129,"sku":"AMU-1821","price":55.0,"currency_code":"USD","in_stock":true},{"title":"18° Deg \/ 5.0 mm","offer_id":40071915896897,"sku":"AMU-1831","price":55.0,"currency_code":"USD","in_stock":true},{"title":"30° Deg \/ 3.0 mm","offer_id":40071915929665,"sku":"AMU-3001","price":55.0,"currency_code":"USD","in_stock":true},{"title":"30° Deg \/ 4.0 mm","offer_id":40071915962433,"sku":"AMU-3011","price":55.0,"currency_code":"USD","in_stock":true},{"title":"30° Deg \/ 5.0 mm","offer_id":40071915995201,"sku":"AMU-3021","price":55.0,"currency_code":"USD","in_stock":true},{"title":"30° Deg \/ 6.0 mm","offer_id":40071916027969,"sku":"AMU-3031","price":55.0,"currency_code":"USD","in_stock":true},{"title":"45° Deg \/ 4.5 mm","offer_id":40071916060737,"sku":"AMU-100005","price":55.0,"currency_code":"USD","in_stock":true},{"title":"45° Deg \/ 6.0 mm","offer_id":40071916093505,"sku":"AMU-100064","price":55.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0558\/0180\/6913\/products\/angular_multi_unit_abutment_prime_coating_internal_hex_2.42.jpg?v=1758453678"},{"product_id":"straight-ball-attachment-prime-coating","title":"Straight Ball Attachment","description":"\u003cp data-start=\"523\" data-end=\"872\"\u003eSurcam’s \u003cstrong data-start=\"532\" data-end=\"573\"\u003eStraight Ball Attachment (PVD Coated)\u003c\/strong\u003e provides a durable, high-performance solution for implant-retained overdenture restorations. The precision-machined ball head features a \u003cstrong data-start=\"711\" data-end=\"726\"\u003ePVD coating\u003c\/strong\u003e that significantly enhances wear resistance, reduces friction, and extends the longevity of the attachment especially under high functional load.\u003c\/p\u003e\n\u003cp data-start=\"874\" data-end=\"1144\"\u003eThis system includes a \u003cstrong data-start=\"897\" data-end=\"914\"\u003emetal housing\u003c\/strong\u003e and a \u003cstrong data-start=\"921\" data-end=\"940\"\u003esilicone insert\u003c\/strong\u003e, forming a reliable retention interface for daily patient use. The straight design ensures simple alignment, predictable seating, and consistent engagement with standard O-ring style overdenture systems.\u003c\/p\u003e\n\u003cp data-start=\"1146\" data-end=\"1307\"\u003eIdeal for both new overdenture cases and replacement during maintenance appointments, offering excellent durability, comfort, and long-term clinical performance.\u003c\/p\u003e\n\u003cul data-start=\"1339\" data-end=\"1737\"\u003e\n\u003cli data-start=\"1339\" data-end=\"1396\"\u003e\n\u003cp data-start=\"1341\" data-end=\"1396\"\u003eStraight ball attachment with premium \u003cstrong data-start=\"1379\" data-end=\"1394\"\u003ePVD coating\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1397\" data-end=\"1461\"\u003e\n\u003cp data-start=\"1399\" data-end=\"1461\"\u003eEnhanced hardness, wear resistance, and corrosion protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1462\" data-end=\"1514\"\u003e\n\u003cp data-start=\"1464\" data-end=\"1514\"\u003eSmooth retention and stable overdenture function\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1515\" data-end=\"1575\"\u003e\n\u003cp data-start=\"1517\" data-end=\"1575\"\u003eIncludes \u003cstrong data-start=\"1526\" data-end=\"1546\"\u003e1× metal housing\u003c\/strong\u003e and \u003cstrong data-start=\"1551\" data-end=\"1573\"\u003e1× silicone insert\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1576\" data-end=\"1635\"\u003e\n\u003cp data-start=\"1578\" data-end=\"1635\"\u003eCompatible with standard O-ring ball attachment systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1636\" data-end=\"1686\"\u003e\n\u003cp data-start=\"1638\" data-end=\"1686\"\u003eReliable seating and long-term patient comfort\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1687\" data-end=\"1737\"\u003e\n\u003cp data-start=\"1689\" data-end=\"1737\"\u003eSuitable for clinical and laboratory workflows\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Surcam","offers":[{"title":"1.0 mm","offer_id":39897849626689,"sku":"BMT-0010-S","price":35.0,"currency_code":"USD","in_stock":true},{"title":"2.0 mm","offer_id":39897849659457,"sku":"BMT-0020-S","price":35.0,"currency_code":"USD","in_stock":true},{"title":"3.0 mm","offer_id":39897849692225,"sku":"BMT-0030-S","price":35.0,"currency_code":"USD","in_stock":true},{"title":"4.0 mm","offer_id":39897849724993,"sku":"BMT-0040-S","price":35.0,"currency_code":"USD","in_stock":true},{"title":"5.0 mm","offer_id":39897849757761,"sku":"BMT-0050-S","price":35.0,"currency_code":"USD","in_stock":true},{"title":"6.0 mm","offer_id":39897849790529,"sku":"BMT-0060-S","price":35.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0558\/0180\/6913\/files\/BMT-0030_ALL_Shopify.jpg?v=1750085686"},{"product_id":"straight-curve-concave-minor-ih-2-42","title":"Straight Curve Concave Minor","description":"\u003ch2 data-start=\"31\" data-end=\"115\"\u003eSlim concave abutment for IH 2.42—soft-tissue shaping in tight spaces (GH 1–4 mm)\u003c\/h2\u003e\n\u003cp data-start=\"141\" data-end=\"852\"\u003eThe \u003cstrong data-start=\"145\" data-end=\"184\"\u003eSurcam Straight Curve Concave Minor\u003c\/strong\u003e is a \u003cstrong data-start=\"190\" data-end=\"238\"\u003estraight, slim-profile transmucosal abutment\u003c\/strong\u003e engineered to sculpt soft tissue and deliver a \u003cstrong data-start=\"286\" data-end=\"315\"\u003eclean, esthetic emergence\u003c\/strong\u003e where space is limited. Its \u003cstrong data-start=\"344\" data-end=\"362\"\u003econcave collar\u003c\/strong\u003e promotes papilla support and cleansability, while \u003cstrong data-start=\"413\" data-end=\"445\"\u003eGrade 5 titanium (Ti-6Al-4V)\u003c\/strong\u003e ensures strength and precise indexing on \u003cstrong data-start=\"487\" data-end=\"511\"\u003eInternal Hex 2.42 mm\u003c\/strong\u003e implants. Ideal for \u003cstrong data-start=\"532\" data-end=\"565\"\u003ecement-retained single crowns\u003c\/strong\u003e and \u003cstrong data-start=\"570\" data-end=\"592\"\u003eshort-span bridges\u003c\/strong\u003e.\u003cbr data-start=\"593\" data-end=\"596\"\u003e\u003cstrong data-start=\"596\" data-end=\"609\"\u003eIncludes:\u003c\/strong\u003e 1× Straight Curve Concave Minor Abutment, 1× Prosthetic Screw.\u003cbr data-start=\"672\" data-end=\"675\"\u003e\u003cstrong data-start=\"675\" data-end=\"693\"\u003eCompatibility:\u003c\/strong\u003e Internal Hex \u003cstrong data-start=\"707\" data-end=\"718\"\u003e2.42 mm\u003c\/strong\u003e; brand families such as \u003cstrong data-start=\"743\" data-end=\"757\"\u003eAlpha Bio®\u003c\/strong\u003e, \u003cstrong data-start=\"759\" data-end=\"770\"\u003eZimmer®\u003c\/strong\u003e, \u003cstrong data-start=\"772\" data-end=\"780\"\u003eMIS®\u003c\/strong\u003e, \u003cstrong data-start=\"782\" data-end=\"791\"\u003eAdin®\u003c\/strong\u003e, \u003cstrong data-start=\"793\" data-end=\"812\"\u003eImplant Direct®\u003c\/strong\u003e, \u003cstrong data-start=\"814\" data-end=\"828\"\u003eAB Dental®\u003c\/strong\u003e (verify interface\/fit).\u003c\/p\u003e\n\u003chr data-start=\"854\" data-end=\"857\"\u003e\n\u003ch2 data-start=\"859\" data-end=\"870\"\u003eBenefits\u003c\/h2\u003e\n\u003cul data-start=\"871\" data-end=\"1339\"\u003e\n\u003cli data-start=\"871\" data-end=\"981\"\u003e\n\u003cp data-start=\"873\" data-end=\"981\"\u003e\u003cstrong data-start=\"873\" data-end=\"903\"\u003eMinor\/small collar profile\u003c\/strong\u003e minimizes subgingival bulk—perfect for narrow embrasures and thin biotypes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"982\" data-end=\"1081\"\u003e\n\u003cp data-start=\"984\" data-end=\"1081\"\u003e\u003cstrong data-start=\"984\" data-end=\"1015\"\u003eConcave transmucosal design\u003c\/strong\u003e guides natural soft-tissue architecture and cleansable margins.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1082\" data-end=\"1160\"\u003e\n\u003cp data-start=\"1084\" data-end=\"1160\"\u003e\u003cstrong data-start=\"1084\" data-end=\"1125\"\u003ePredictable cement-retained workflows\u003c\/strong\u003e with straight path of insertion.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1161\" data-end=\"1252\"\u003e\n\u003cp data-start=\"1163\" data-end=\"1252\"\u003e\u003cstrong data-start=\"1163\" data-end=\"1192\"\u003eMultiple gingival heights\u003c\/strong\u003e (\u003cstrong data-start=\"1194\" data-end=\"1222\"\u003e1.0 \/ 2.0 \/ 3.0 \/ 4.0 mm\u003c\/strong\u003e) to match tissue thickness.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1253\" data-end=\"1339\"\u003e\n\u003cp data-start=\"1255\" data-end=\"1339\"\u003e\u003cstrong data-start=\"1255\" data-end=\"1275\"\u003eGrade 5 titanium\u003c\/strong\u003e durability and biocompatibility for daily clinical reliability.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1341\" data-end=\"1344\"\u003e\n\u003ch2 data-start=\"1346\" data-end=\"1364\"\u003eProduct Details\u003c\/h2\u003e\n\u003cul data-start=\"1365\" data-end=\"1928\"\u003e\n\u003cli data-start=\"1365\" data-end=\"1424\"\u003e\n\u003cp data-start=\"1367\" data-end=\"1424\"\u003e\u003cstrong data-start=\"1367\" data-end=\"1393\"\u003eConnection \/ Platform:\u003c\/strong\u003e \u003cstrong data-start=\"1394\" data-end=\"1422\"\u003eInternal Hexagon 2.42 mm\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1425\" data-end=\"1475\"\u003e\n\u003cp data-start=\"1427\" data-end=\"1475\"\u003e\u003cstrong data-start=\"1427\" data-end=\"1440\"\u003eMaterial:\u003c\/strong\u003e \u003cstrong data-start=\"1441\" data-end=\"1473\"\u003eTitanium Grade 5 (Ti-6Al-4V)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1476\" data-end=\"1539\"\u003e\n\u003cp data-start=\"1478\" data-end=\"1539\"\u003e\u003cstrong data-start=\"1478\" data-end=\"1502\"\u003eTransmucosal Design:\u003c\/strong\u003e \u003cstrong data-start=\"1503\" data-end=\"1530\"\u003eConcave, slim (“Minor”)\u003c\/strong\u003e collar\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1540\" data-end=\"1599\"\u003e\n\u003cp data-start=\"1542\" data-end=\"1599\"\u003e\u003cstrong data-start=\"1542\" data-end=\"1568\"\u003eGingival Heights (GH):\u003c\/strong\u003e \u003cstrong data-start=\"1569\" data-end=\"1597\"\u003e1.0 \/ 2.0 \/ 3.0 \/ 4.0 mm\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1600\" data-end=\"1674\"\u003e\n\u003cp data-start=\"1602\" data-end=\"1674\"\u003e\u003cstrong data-start=\"1602\" data-end=\"1620\"\u003ePack Contents:\u003c\/strong\u003e \u003cstrong data-start=\"1621\" data-end=\"1636\"\u003e1× Abutment\u003c\/strong\u003e, \u003cstrong data-start=\"1638\" data-end=\"1672\"\u003e1× Prosthetic (abutment) Screw\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1675\" data-end=\"1928\"\u003e\n\u003cp data-start=\"1677\" data-end=\"1928\"\u003e\u003cstrong data-start=\"1677\" data-end=\"1701\"\u003eBrand Compatibility:\u003c\/strong\u003e Alpha Bio®, Zimmer®, MIS®, Adin®, Implant Direct®, AB Dental®*\u003cbr data-start=\"1764\" data-end=\"1767\"\u003e* Always verify platform dimensions and interface prior to clinical use. Trademarks belong to their respective owners and are referenced for compatibility only.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1930\" data-end=\"1933\"\u003e\n\u003ch2 data-start=\"1935\" data-end=\"1952\"\u003eSpecifications\u003c\/h2\u003e\n\u003cul data-start=\"1953\" data-end=\"2330\"\u003e\n\u003cli data-start=\"1953\" data-end=\"2065\"\u003e\n\u003cp data-start=\"1955\" data-end=\"2065\"\u003e\u003cstrong data-start=\"1955\" data-end=\"1971\"\u003eIndications:\u003c\/strong\u003e Cement-retained single crowns \u0026amp; short-span bridges—anterior or posterior with limited space\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2066\" data-end=\"2157\"\u003e\n\u003cp data-start=\"2068\" data-end=\"2157\"\u003e\u003cstrong data-start=\"2068\" data-end=\"2087\"\u003eSeating\/Torque:\u003c\/strong\u003e Verify \u003cstrong data-start=\"2095\" data-end=\"2120\"\u003efull seating\/indexing\u003c\/strong\u003e; \u003cstrong data-start=\"2122\" data-end=\"2155\"\u003etorque per implant system IFU\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2158\" data-end=\"2245\"\u003e\n\u003cp data-start=\"2160\" data-end=\"2245\"\u003e\u003cstrong data-start=\"2160\" data-end=\"2172\"\u003eMargins:\u003c\/strong\u003e Concave minor collar supports shallow, \u003cstrong data-start=\"2212\" data-end=\"2243\"\u003ecleansable cervical margins\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2246\" data-end=\"2330\"\u003e\n\u003cp data-start=\"2248\" data-end=\"2330\"\u003e\u003cstrong data-start=\"2248\" data-end=\"2261\"\u003eWorkflow:\u003c\/strong\u003e Compatible with conventional impressions and \u003cstrong data-start=\"2307\" data-end=\"2318\"\u003eCAD\/CAM\u003c\/strong\u003e prosthetics\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2332\" data-end=\"2335\"\u003e\n\u003ch2 data-start=\"2337\" data-end=\"2372\"\u003eWhy Choose Surcam Concave Minor?\u003c\/h2\u003e\n\u003cul data-start=\"2373\" data-end=\"2574\"\u003e\n\u003cli data-start=\"2373\" data-end=\"2433\"\u003e\n\u003cp data-start=\"2375\" data-end=\"2433\"\u003eOptimized \u003cstrong data-start=\"2385\" data-end=\"2410\"\u003esoft-tissue esthetics\u003c\/strong\u003e in \u003cstrong data-start=\"2414\" data-end=\"2431\"\u003enarrow spaces\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2434\" data-end=\"2506\"\u003e\n\u003cp data-start=\"2436\" data-end=\"2506\"\u003e\u003cstrong data-start=\"2436\" data-end=\"2460\"\u003eCleansable emergence\u003c\/strong\u003e that supports long-term peri-implant health\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2507\" data-end=\"2574\"\u003e\n\u003cp data-start=\"2509\" data-end=\"2574\"\u003e\u003cstrong data-start=\"2509\" data-end=\"2532\"\u003ePrecision machining\u003c\/strong\u003e for repeatable, secure seating on IH 2.42\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2576\" data-end=\"2579\"\u003e\n\u003ch2 data-start=\"2337\" data-end=\"2372\"\u003eSurcam Concave Minor FAQs\u003c\/h2\u003e\n\u003ch3 data-start=\"2589\" data-end=\"2632\"\u003eWhich implant platforms are compatible?\u003c\/h3\u003e\n\u003cp data-start=\"2633\" data-end=\"2802\"\u003eInternal Hex \u003cstrong data-start=\"2646\" data-end=\"2657\"\u003e2.42 mm\u003c\/strong\u003e systems including \u003cstrong data-start=\"2676\" data-end=\"2741\"\u003eAlpha Bio®, Zimmer®, MIS®, Adin®, Implant Direct®, AB Dental®\u003c\/strong\u003e. Always verify platform dimensions and interface before use.\u003c\/p\u003e\n\u003ch3 data-start=\"2804\" data-end=\"2848\"\u003eWhat does “Minor” mean in this abutment?\u003c\/h3\u003e\n\u003cp data-start=\"2849\" data-end=\"3003\"\u003e“\u003cstrong data-start=\"2850\" data-end=\"2859\"\u003eMinor\u003c\/strong\u003e” refers to a \u003cstrong data-start=\"2873\" data-end=\"2913\"\u003ereduced transmucosal collar diameter\u003c\/strong\u003e, ideal for tight embrasures, thin tissue, and cases that need minimal subgingival volume.\u003c\/p\u003e\n\u003ch3 data-start=\"3005\" data-end=\"3045\"\u003eHow do I choose the gingival height?\u003c\/h3\u003e\n\u003cp data-start=\"3046\" data-end=\"3236\"\u003eMatch GH to \u003cstrong data-start=\"3058\" data-end=\"3079\"\u003emucosal thickness\u003c\/strong\u003e and emergence goals: thin tissue → \u003cstrong data-start=\"3115\" data-end=\"3125\"\u003e1.0 mm\u003c\/strong\u003e; average → \u003cstrong data-start=\"3137\" data-end=\"3147\"\u003e2.0 mm\u003c\/strong\u003e; thicker biotype\/convex emergence → \u003cstrong data-start=\"3184\" data-end=\"3198\"\u003e3.0–4.0 mm\u003c\/strong\u003e. Confirm clinically\/radiographically.\u003c\/p\u003e\n\u003ch3 data-start=\"3238\" data-end=\"3301\"\u003eIs this for cement-retained or screw-retained restorations?\u003c\/h3\u003e\n\u003cp data-start=\"3302\" data-end=\"3428\"\u003ePrimarily \u003cstrong data-start=\"3312\" data-end=\"3331\"\u003ecement-retained\u003c\/strong\u003e. The included screw secures the \u003cstrong data-start=\"3364\" data-end=\"3391\"\u003eabutment to the implant\u003c\/strong\u003e; cement the crown per your protocol.\u003c\/p\u003e\n\u003ch3 data-start=\"3430\" data-end=\"3461\"\u003eWhat torque should I apply?\u003c\/h3\u003e\n\u003cp data-start=\"3462\" data-end=\"3587\"\u003eUse the \u003cstrong data-start=\"3470\" data-end=\"3503\"\u003emanufacturer-specified torque\u003c\/strong\u003e for IH 2.42 abutments in your system \u003cstrong data-start=\"3541\" data-end=\"3548\"\u003eIFU\u003c\/strong\u003e; do \u003cstrong data-start=\"3553\" data-end=\"3560\"\u003enot\u003c\/strong\u003e exceed recommended values.\u003c\/p\u003e\n\u003ch3 data-start=\"3589\" data-end=\"3649\"\u003eIs it suitable for anterior esthetics and narrow spaces?\u003c\/h3\u003e\n\u003cp data-start=\"3650\" data-end=\"3778\"\u003eYes. The \u003cstrong data-start=\"3659\" data-end=\"3682\"\u003eslim concave collar\u003c\/strong\u003e supports papillae and esthetic emergence in \u003cstrong data-start=\"3727\" data-end=\"3747\"\u003ecrowded anterior\u003c\/strong\u003e or \u003cstrong data-start=\"3751\" data-end=\"3771\"\u003enarrow posterior\u003c\/strong\u003e sites.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\":\"https:\/\/schema.org\",\n  \"@type\":\"FAQPage\",\n  \"inLanguage\":\"en\",\n  \"mainEntity\":[\n    {\n      \"@type\":\"Question\",\n      \"name\":\"Which implant platforms are compatible?\",\n      \"acceptedAnswer\":{\n        \"@type\":\"Answer\",\n        \"text\":\"Internal Hex 2.42 mm systems including Alpha Bio®, Zimmer®, MIS®, Adin®, Implant Direct®, and AB Dental®. Always verify platform dimensions and interface before clinical use.\"\n      }\n    },\n    {\n      \"@type\":\"Question\",\n      \"name\":\"What does “Minor” mean in this abutment?\",\n      \"acceptedAnswer\":{\n        \"@type\":\"Answer\",\n        \"text\":\"“Minor” indicates a reduced transmucosal collar diameter, suited to narrow embrasures and thin tissue where minimal subgingival volume and a cleansable emergence are desired.\"\n      }\n    },\n    {\n      \"@type\":\"Question\",\n      \"name\":\"How do I choose the gingival height?\",\n      \"acceptedAnswer\":{\n        \"@type\":\"Answer\",\n        \"text\":\"Select 1.0 mm for thin tissue, 2.0 mm for average tissue, and 3.0–4.0 mm for thicker biotypes or a more convex emergence. Confirm clinically and radiographically.\"\n      }\n    },\n    {\n      \"@type\":\"Question\",\n      \"name\":\"Is this for cement-retained or screw-retained restorations?\",\n      \"acceptedAnswer\":{\n        \"@type\":\"Answer\",\n        \"text\":\"It is primarily for cement-retained restorations. The included screw secures the abutment to the implant; follow your system’s protocol for crown cementation.\"\n      }\n    },\n    {\n      \"@type\":\"Question\",\n      \"name\":\"What torque should be applied?\",\n      \"acceptedAnswer\":{\n        \"@type\":\"Answer\",\n        \"text\":\"Apply the torque specified in your implant system’s IFU for Internal Hex 2.42 abutments. Do not exceed manufacturer values.\"\n      }\n    },\n    {\n      \"@type\":\"Question\",\n      \"name\":\"Is it suitable for anterior esthetics and narrow spaces?\",\n      \"acceptedAnswer\":{\n        \"@type\":\"Answer\",\n        \"text\":\"Yes. The slim concave collar supports papillae and an esthetic emergence in crowded anterior or narrow posterior sites when paired with proper prosthetic design.\"\n      }\n    }\n  ]\n}\n\u003c\/script\u003e\n","brand":"Surcam","offers":[{"title":"1.0 mm","offer_id":39897908281409,"sku":"SCCM-1110","price":15.0,"currency_code":"USD","in_stock":true},{"title":"2.0 mm","offer_id":39897908314177,"sku":"SCCM-1220","price":15.0,"currency_code":"USD","in_stock":true},{"title":"3.0 mm","offer_id":39897908346945,"sku":"SCCM-1330","price":15.0,"currency_code":"USD","in_stock":true},{"title":"4.0 mm","offer_id":39897908379713,"sku":"SCCM-1440","price":15.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0558\/0180\/6913\/files\/SCCM-All_Shopify.jpg?v=1750085561"},{"product_id":"3d-scan-body-lab-device-for-prime-multi-unit","title":"3D Scan Body Lab Device For Prime Multi-Unit","description":"\u003cp\u003eThe lab version of the Surcam \u003cstrong\u003e3D scan body for Prime Multi-Unit\u003c\/strong\u003e. It is screwed onto the multi-unit analog in the model and captured with a desktop scanner, and the CAD software matches it to the library file to place each multi-unit position in the design.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIncludes:\u003c\/strong\u003e 1 laboratory scan body and 1 prosthetic screw\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial:\u003c\/strong\u003e titanium Grade 5 (Ti-6Al-4V)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatible with:\u003c\/strong\u003e Surcam Prime Multi-Unit (1-72 UNF screw)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCatalog code:\u003c\/strong\u003e TSU-100055\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFor scanning in the mouth, use the \u003ca href=\"https:\/\/surcamdental.shop\/products\/3d-scan-body-intraoral-device-for-prime-multi-unit\"\u003eintraoral version\u003c\/a\u003e. Download the matching file from the \u003ca href=\"https:\/\/surcamdental.shop\/pages\/digital-libraries\"\u003edigital libraries\u003c\/a\u003e page.\u003c\/p\u003e\n\u003ch2\u003eRelated parts\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/surcamdental.shop\/collections\/implant-scan-bodies\"\u003eAll implant scan bodies\u003c\/a\u003e · \u003ca href=\"https:\/\/surcamdental.shop\/products\/ti-base-for-cad-cam-on-prime-multi-unit\"\u003eTi-base for Prime Multi-Unit\u003c\/a\u003e · \u003ca href=\"https:\/\/surcamdental.shop\/products\/digital-analog-for-multi-unit\"\u003edigital analog for Prime Multi-Unit\u003c\/a\u003e\u003c\/p\u003e","brand":"Surcam","offers":[{"title":"Default Title","offer_id":39915316215873,"sku":"TSU-100055","price":20.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0558\/0180\/6913\/products\/TSU-100055.1_Shopify_b0bdd60d-4561-4912-9168-4afa419c739a.jpg?v=1658305615"},{"product_id":"general-straight-multi-unit","title":"General Straight Multi-Unit","description":"\u003cp\u003eThe Surcam straight \u003cstrong\u003eGeneral Multi-Unit abutment\u003c\/strong\u003e brings an implant up to a common restorative level at the soft tissue, so a screw-retained bridge or full-arch prosthesis can seat passively and stay retrievable. Use it when the implant is close to parallel with the planned path of insertion.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIncludes:\u003c\/strong\u003e 1 straight General Multi-Unit abutment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGingival height:\u003c\/strong\u003e 1.0, 2.0, 3.0, 4.0 or 5.0 mm (catalog codes EMU-130007 to EMU-130011)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial:\u003c\/strong\u003e titanium Grade 5 (Ti-6Al-4V)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection:\u003c\/strong\u003e internal hexagon 2.42 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatible brands:\u003c\/strong\u003e Alpha-Bio®, Zimmer®, MIS®, Adin®, Implant Direct®, AB Dental®\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eCompleting the restoration\u003c\/h2\u003e\n\u003cp\u003eSeat the abutment with the \u003ca href=\"https:\/\/surcamdental.shop\/products\/straight-driver-for-general-multi-unit\"\u003estraight General Multi-Unit driver\u003c\/a\u003e and protect it with a \u003ca href=\"https:\/\/surcamdental.shop\/products\/healing-cap-for-general-multi-unit\"\u003eGeneral Multi-Unit healing cap\u003c\/a\u003e until the restoration is ready. The prosthetic screw for the bridge is not included: it comes with the General Multi-Unit sleeves and Ti-bases, or in \u003ca href=\"https:\/\/surcamdental.shop\/products\/10x-prosthetic-screw-general-multi-unit-abutment\"\u003e10-packs\u003c\/a\u003e. Tighten to the IFU value; the Surcam catalog states multi-unit screws must never exceed 15 Ncm.\u003c\/p\u003e\n\u003ch2\u003eRelated parts\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/surcamdental.shop\/products\/angular-general-multi-unit-abutment\"\u003eAngled General Multi-Unit abutment\u003c\/a\u003e · \u003ca href=\"https:\/\/surcamdental.shop\/collections\/internal-hex-multi-unit\"\u003eGeneral Multi-Unit components\u003c\/a\u003e · \u003ca href=\"https:\/\/surcamdental.shop\/collections\/multi-unit\"\u003eall multi-unit abutments\u003c\/a\u003e\u003c\/p\u003e","brand":"Surcam","offers":[{"title":"1.0 mm","offer_id":39931770601537,"sku":"EMU-130007","price":40.0,"currency_code":"USD","in_stock":true},{"title":"2.0 mm","offer_id":39931770634305,"sku":"EMU-130008","price":40.0,"currency_code":"USD","in_stock":true},{"title":"3.0 mm","offer_id":39931770667073,"sku":"EMU-130009","price":40.0,"currency_code":"USD","in_stock":true},{"title":"4.0 mm","offer_id":39931770699841,"sku":"EMU-130010","price":40.0,"currency_code":"USD","in_stock":true},{"title":"5.0 mm","offer_id":39931770732609,"sku":"EMU-130011","price":40.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0558\/0180\/6913\/files\/EMU_1300_All_Shopify.jpg?v=1750085334"},{"product_id":"angular-general-multi-unit-abutment","title":"Angular General Multi-Unit Abutment","description":"\u003cp data-start=\"649\" data-end=\"1000\"\u003eThe \u003cstrong data-start=\"653\" data-end=\"715\"\u003eAngular General Multi-Unit Abutment – Internal Hex 2.42 mm\u003c\/strong\u003e is designed for screw-retained prosthetic solutions, providing a reliable restorative option for implants placed at challenging angles. Made from premium \u003cstrong data-start=\"870\" data-end=\"902\"\u003eTitanium Grade 5 (Ti-6Al-4V)\u003c\/strong\u003e, this abutment delivers excellent strength, biocompatibility, and long-term mechanical stability.\u003c\/p\u003e\n\u003cp data-start=\"1002\" data-end=\"1308\"\u003eThis angular abutment is ideal for full-arch and partial-arch restorations where implant angulation must be corrected to achieve optimal prosthetic seating. The design allows for predictable load distribution, secure screw retention, and compatibility with a wide range of multi-unit prosthetic components.\u003c\/p\u003e\n\u003cp data-start=\"1310\" data-end=\"1642\"\u003eSURCAM’s multi-unit system is engineered for cases involving tilted implants, offering a low-profile connection available in multiple angles—including straight, 18°, 30°, and 45°—with various gingival heights. This versatility ensures precision alignment and simplified restorative workflows for upper and lower jaw rehabilitations.\u003c\/p\u003e\n\u003cp data-start=\"1644\" data-end=\"1664\"\u003e\u003cstrong data-start=\"1644\" data-end=\"1662\"\u003ePack includes:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1665\" data-end=\"1751\"\u003e\n\u003cli data-start=\"1665\" data-end=\"1707\"\u003e\n\u003cp data-start=\"1667\" data-end=\"1707\"\u003e1× Angular General Multi-Unit Abutment\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1708\" data-end=\"1731\"\u003e\n\u003cp data-start=\"1710\" data-end=\"1731\"\u003e1× Prosthetic Screw\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1732\" data-end=\"1751\"\u003e\n\u003cp data-start=\"1734\" data-end=\"1751\"\u003e1× Stick Holder\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1753\" data-end=\"1880\"\u003e\u003cstrong data-start=\"1753\" data-end=\"1803\"\u003eCompatible with Internal Hex 2.42 mm platforms\u003c\/strong\u003e, including:\u003cbr data-start=\"1815\" data-end=\"1818\"\u003eAlpha Bio®, Zimmer®, MIS®, Adin®, Implant Direct®, AB Dental®.\u003c\/p\u003e\n\u003cul data-start=\"1911\" data-end=\"2509\"\u003e\n\u003cli data-start=\"1911\" data-end=\"1974\"\u003e\n\u003cp data-start=\"1913\" data-end=\"1974\"\u003eAngular multi-unit abutment for screw-retained restorations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1975\" data-end=\"2043\"\u003e\n\u003cp data-start=\"1977\" data-end=\"2043\"\u003eCorrects implant angulation for full-arch and partial-arch cases\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2044\" data-end=\"2082\"\u003e\n\u003cp data-start=\"2046\" data-end=\"2082\"\u003eInternal Hex 2.42 mm compatibility\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2083\" data-end=\"2137\"\u003e\n\u003cp data-start=\"2085\" data-end=\"2137\"\u003eManufactured from \u003cstrong data-start=\"2103\" data-end=\"2135\"\u003eTitanium Grade 5 (Ti-6Al-4V)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2138\" data-end=\"2210\"\u003e\n\u003cp data-start=\"2140\" data-end=\"2210\"\u003eLow-profile connection ideal for esthetic and functional restoration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2211\" data-end=\"2275\"\u003e\n\u003cp data-start=\"2213\" data-end=\"2275\"\u003eStable, durable interface for predictable prosthetic seating\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2276\" data-end=\"2339\"\u003e\n\u003cp data-start=\"2278\" data-end=\"2339\"\u003e\u003cstrong data-start=\"2278\" data-end=\"2296\"\u003ePack includes:\u003c\/strong\u003e abutment, prosthetic screw, stick holder\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2340\" data-end=\"2444\"\u003e\n\u003cp data-start=\"2342\" data-end=\"2444\"\u003eCompatible with major implant systems: Alpha Bio®, Zimmer®, MIS®, Adin®, Implant Direct®, AB Dental®\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2445\" data-end=\"2509\"\u003e\n\u003cp data-start=\"2447\" data-end=\"2509\"\u003eSuitable for multi-unit bridges, bars, and hybrid prostheses\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Surcam","offers":[{"title":"18° Deg \/ 2.0 mm","offer_id":39931779317825,"sku":"AMU-130004","price":55.0,"currency_code":"USD","in_stock":true},{"title":"18° Deg \/ 3.0 mm","offer_id":40072610512961,"sku":"AMU-130005","price":55.0,"currency_code":"USD","in_stock":true},{"title":"18° Deg \/ 4.0 mm","offer_id":40072610545729,"sku":"AMU-130006","price":55.0,"currency_code":"USD","in_stock":true},{"title":"18° Deg \/ 5.0 mm","offer_id":40072610578497,"sku":"AMU-130028","price":55.0,"currency_code":"USD","in_stock":true},{"title":"30° Deg \/ 3.0 mm","offer_id":40072610644033,"sku":"AMU-130001","price":55.0,"currency_code":"USD","in_stock":true},{"title":"30° Deg \/ 4.0 mm","offer_id":40072610676801,"sku":"AMU-130002","price":55.0,"currency_code":"USD","in_stock":true},{"title":"30° Deg \/ 5.0 mm","offer_id":40072610709569,"sku":"AMU-130003","price":55.0,"currency_code":"USD","in_stock":true},{"title":"45° Deg \/ 4.0 mm","offer_id":40072610807873,"sku":"AMU-130014","price":55.0,"currency_code":"USD","in_stock":true},{"title":"45° Deg \/ 6.0 mm","offer_id":40072610873409,"sku":"AMU-130027","price":55.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0558\/0180\/6913\/products\/AMU-130004.1_Shopify.jpg?v=1658142822"},{"product_id":"open-tray-transfer-for-general-multi-unit","title":"Open Tray Transfer For General Multi-Unit","description":"\u003cp\u003eAn open-tray impression transfer for Surcam \u003cstrong\u003eGeneral Multi-Unit\u003c\/strong\u003e abutments. The long transfer screw passes through a window in the tray, so the transfer stays captured in the impression when the tray is removed. Open-tray transfers are preferred for multiple and non-parallel implants and for full-arch cases.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIncludes:\u003c\/strong\u003e 1 open-tray transfer and 1 long prosthetic screw for the transfer\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial:\u003c\/strong\u003e titanium Grade 5 (Ti-6Al-4V)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatible with:\u003c\/strong\u003e Surcam General Multi-Unit system\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eClean and sterilize before intraoral use as described in the IFU.\u003c\/p\u003e\n\u003ch2\u003eRelated parts\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/surcamdental.shop\/products\/analog-general-multi-unit\"\u003eLab analog for General Multi-Unit\u003c\/a\u003e · \u003ca href=\"https:\/\/surcamdental.shop\/products\/closed-tray-transfer-for-general-multi-unit\"\u003eclosed-tray transfer for General Multi-Unit\u003c\/a\u003e · \u003ca href=\"https:\/\/surcamdental.shop\/collections\/impression-copings\"\u003eall impression copings\u003c\/a\u003e\u003c\/p\u003e","brand":"Surcam","offers":[{"title":"Default Title","offer_id":39931806384193,"sku":"TM-300068","price":15.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0558\/0180\/6913\/files\/TM-300068.1_Shopify_6c7f7d47-f1e3-4e0e-b423-fc7c8163db7a.jpg?v=1779788841"},{"product_id":"analog-general-multi-unit","title":"Analog For General Multi-Unit","description":"\u003ch2\u003eTitanium lab analog for general Multi-Unit systems - accurate model indexing \u0026amp; stable seating\u003c\/h2\u003e\n\u003cp data-start=\"152\" data-end=\"660\"\u003eThe \u003cstrong data-start=\"156\" data-end=\"196\"\u003eSurcam Analog For General Multi-Unit\u003c\/strong\u003e replicates the multi-unit abutment interface in \u003cstrong data-start=\"245\" data-end=\"276\"\u003e3D-printed or milled models\u003c\/strong\u003e, enabling precise \u003cstrong data-start=\"295\" data-end=\"318\"\u003eCAD\/CAM fabrication\u003c\/strong\u003e of screw-retained provisional and definitive restorations. Machined from \u003cstrong data-start=\"392\" data-end=\"424\"\u003eTitanium Grade 5 (Ti-6Al-4V)\u003c\/strong\u003e, it delivers durable, repeatable \u003cstrong data-start=\"458\" data-end=\"482\"\u003eindexing and seating\u003c\/strong\u003e that supports full-arch and segmental workflows with predictable fit.\u003cbr data-start=\"552\" data-end=\"555\"\u003e\u003cstrong data-start=\"555\" data-end=\"568\"\u003eIncludes:\u003c\/strong\u003e 1× Analog.\u003cbr data-start=\"579\" data-end=\"582\"\u003e\u003cstrong data-start=\"582\" data-end=\"600\"\u003eCompatibility:\u003c\/strong\u003e \u003cstrong data-start=\"601\" data-end=\"630\"\u003eGeneral Multi-Unit system\u003c\/strong\u003e (verify geometry before use).\u003c\/p\u003e\n\u003chr data-start=\"662\" data-end=\"665\"\u003e\n\u003ch2 data-start=\"667\" data-end=\"678\"\u003eBenefits\u003c\/h2\u003e\n\u003cul data-start=\"679\" data-end=\"1162\"\u003e\n\u003cli data-start=\"679\" data-end=\"782\"\u003e\n\u003cp data-start=\"681\" data-end=\"782\"\u003e\u003cstrong data-start=\"681\" data-end=\"699\"\u003eModel accuracy\u003c\/strong\u003e – Tight tolerances help capture true position\/angulation for passive frameworks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"783\" data-end=\"888\"\u003e\n\u003cp data-start=\"785\" data-end=\"888\"\u003e\u003cstrong data-start=\"785\" data-end=\"803\"\u003eStable seating\u003c\/strong\u003e – Secure lock-in to printed\/milled sockets reduces rotation during lab procedures.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"889\" data-end=\"989\"\u003e\n\u003cp data-start=\"891\" data-end=\"989\"\u003e\u003cstrong data-start=\"891\" data-end=\"908\"\u003eCAD\/CAM ready\u003c\/strong\u003e – Works seamlessly with IOS → design → milling for bridges and full-arch bars.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"990\" data-end=\"1075\"\u003e\n\u003cp data-start=\"992\" data-end=\"1075\"\u003e\u003cstrong data-start=\"992\" data-end=\"1012\"\u003eDurable titanium\u003c\/strong\u003e – \u003cstrong data-start=\"1015\" data-end=\"1026\"\u003eGrade 5\u003c\/strong\u003e construction withstands repeated lab handling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1076\" data-end=\"1162\"\u003e\n\u003cp data-start=\"1078\" data-end=\"1162\"\u003e\u003cstrong data-start=\"1078\" data-end=\"1102\"\u003eWorkflow versatility\u003c\/strong\u003e – Suitable for single, segmental, and full-arch situations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1164\" data-end=\"1167\"\u003e\n\u003ch2 data-start=\"1169\" data-end=\"1187\"\u003eProduct Details\u003c\/h2\u003e\n\u003cul data-start=\"1188\" data-end=\"1388\"\u003e\n\u003cli data-start=\"1188\" data-end=\"1229\"\u003e\n\u003cp data-start=\"1190\" data-end=\"1229\"\u003e\u003cstrong data-start=\"1190\" data-end=\"1204\"\u003eInterface:\u003c\/strong\u003e General \u003cstrong data-start=\"1213\" data-end=\"1227\"\u003eMulti-Unit\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1230\" data-end=\"1280\"\u003e\n\u003cp data-start=\"1232\" data-end=\"1280\"\u003e\u003cstrong data-start=\"1232\" data-end=\"1245\"\u003eMaterial:\u003c\/strong\u003e \u003cstrong data-start=\"1246\" data-end=\"1278\"\u003eTitanium Grade 5 (Ti-6Al-4V)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1281\" data-end=\"1317\"\u003e\n\u003cp data-start=\"1283\" data-end=\"1317\"\u003e\u003cstrong data-start=\"1283\" data-end=\"1301\"\u003ePack Contents:\u003c\/strong\u003e \u003cstrong data-start=\"1302\" data-end=\"1315\"\u003e1× Analog\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1318\" data-end=\"1388\"\u003e\n\u003cp data-start=\"1320\" data-end=\"1388\"\u003e\u003cstrong data-start=\"1320\" data-end=\"1328\"\u003eUse:\u003c\/strong\u003e \u003cstrong data-start=\"1329\" data-end=\"1358\"\u003eLaboratory\/model use only\u003c\/strong\u003e (not for intraoral placement)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1390\" data-end=\"1393\"\u003e\n\u003ch2 data-start=\"1395\" data-end=\"1412\"\u003eSpecifications\u003c\/h2\u003e\n\u003cul data-start=\"1413\" data-end=\"1713\"\u003e\n\u003cli data-start=\"1413\" data-end=\"1506\"\u003e\n\u003cp data-start=\"1415\" data-end=\"1506\"\u003eSeats into \u003cstrong data-start=\"1426\" data-end=\"1456\"\u003e3D-printed or milled model\u003c\/strong\u003e sockets; verify full seating \u0026amp; rotational index\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1507\" data-end=\"1579\"\u003e\n\u003cp data-start=\"1509\" data-end=\"1579\"\u003eFollow your \u003cstrong data-start=\"1521\" data-end=\"1540\"\u003eCAD\/CAM library\u003c\/strong\u003e for socket dimensions and tolerances\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1580\" data-end=\"1646\"\u003e\n\u003cp data-start=\"1582\" data-end=\"1646\"\u003eClean\/inspect seating surfaces to maintain \u003cstrong data-start=\"1625\" data-end=\"1644\"\u003emodel precision\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1647\" data-end=\"1713\"\u003e\n\u003cp data-start=\"1649\" data-end=\"1713\"\u003eCompatible with standard \u003cstrong data-start=\"1674\" data-end=\"1692\"\u003escrew-retained\u003c\/strong\u003e prosthetic workflows\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1715\" data-end=\"1718\"\u003e\n\u003ch2 data-start=\"1720\" data-end=\"1749\"\u003eWhy Choose Surcam Analogs?\u003c\/h2\u003e\n\u003cul data-start=\"1750\" data-end=\"1938\"\u003e\n\u003cli data-start=\"1750\" data-end=\"1818\"\u003e\n\u003cp data-start=\"1752\" data-end=\"1818\"\u003eConsistent \u003cstrong data-start=\"1763\" data-end=\"1783\"\u003efit and indexing\u003c\/strong\u003e for predictable CAD\/CAM outcomes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1819\" data-end=\"1879\"\u003e\n\u003cp data-start=\"1821\" data-end=\"1879\"\u003e\u003cstrong data-start=\"1821\" data-end=\"1841\"\u003eGrade 5 titanium\u003c\/strong\u003e longevity and dimensional stability\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1880\" data-end=\"1938\"\u003e\n\u003cp data-start=\"1882\" data-end=\"1938\"\u003eSmooth integration into modern \u003cstrong data-start=\"1913\" data-end=\"1928\"\u003edigital lab\u003c\/strong\u003e processes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1940\" data-end=\"1943\"\u003e\n\u003ch2 data-start=\"1720\" data-end=\"1749\"\u003eSurcam Analogs FAQs\u003c\/h2\u003e\n\u003ch3 data-start=\"1953\" data-end=\"2002\"\u003eWhich systems is this analog compatible with?\u003c\/h3\u003e\n\u003cp data-start=\"2003\" data-end=\"2111\"\u003eGeneral \u003cstrong data-start=\"2011\" data-end=\"2025\"\u003eMulti-Unit\u003c\/strong\u003e interfaces. Verify the analog geometry against your multi-unit components before use.\u003c\/p\u003e\n\u003ch3 data-start=\"2113\" data-end=\"2159\"\u003eIs this analog intended for intraoral use?\u003c\/h3\u003e\n\u003cp data-start=\"2160\" data-end=\"2244\"\u003eNo. It is \u003cstrong data-start=\"2170\" data-end=\"2182\"\u003elab-only\u003c\/strong\u003e, for printed or milled models to support CAD\/CAM fabrication.\u003c\/p\u003e\n\u003ch3 data-start=\"2246\" data-end=\"2301\"\u003eDoes it work with different 3D printers and resins?\u003c\/h3\u003e\n\u003cp data-start=\"2302\" data-end=\"2407\"\u003eYes. It is \u003cstrong data-start=\"2313\" data-end=\"2333\"\u003eprinter-agnostic\u003c\/strong\u003e—use the correct library and ensure sockets are produced to specification.\u003c\/p\u003e\n\u003ch3 data-start=\"2409\" data-end=\"2459\"\u003eHow do I ensure accurate seating and indexing?\u003c\/h3\u003e\n\u003cp data-start=\"2460\" data-end=\"2577\"\u003eConfirm \u003cstrong data-start=\"2468\" data-end=\"2484\"\u003efull seating\u003c\/strong\u003e and rotational index in the model socket; follow your library’s tolerances and lab protocol.\u003c\/p\u003e\n\u003ch3 data-start=\"2579\" data-end=\"2635\"\u003eWhat prosthetics can be fabricated with this analog?\u003c\/h3\u003e\n\u003cp data-start=\"2636\" data-end=\"2756\"\u003e\u003cstrong data-start=\"2636\" data-end=\"2713\"\u003eScrew-retained single units, short-span bridges, and full-arch frameworks\u003c\/strong\u003e produced via CAD\/CAM from intraoral scans.\u003c\/p\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"FAQPage\",\n  \"inLanguage\": \"en\",\n  \"mainEntity\": [\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Which systems is this analog compatible with?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"General Multi-Unit interfaces. Verify the analog geometry against your multi-unit components and library specifications before use.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Is this analog intended for intraoral use?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"No. It is for laboratory\/model use only in 3D-printed or milled models to support CAD\/CAM fabrication.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Does it work with different 3D printers and resins?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Yes. It is printer-agnostic. Use the correct CAD\/CAM library and ensure sockets are produced to specification for accurate seating and indexing.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"How do I ensure accurate seating and indexing?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Confirm full seating and the proper rotational index in the model socket, and follow the library’s tolerances and lab protocol.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What prosthetics can be fabricated with this analog?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Screw-retained single units, short-span bridges, and full-arch frameworks produced via CAD\/CAM from intraoral scans.\"\n      }\n    }\n  ]\n}\n\u003c\/script\u003e\n","brand":"Surcam","offers":[{"title":"Default Title","offer_id":39931822702657,"sku":"AM-300070","price":15.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0558\/0180\/6913\/products\/AM-300070.1_Shopify.jpg?v=1653816749"},{"product_id":"dasm-300146","title":"Digital Analog For General Multi-Unit","description":"\u003cp\u003eA digital analog for 3D-printed models of Surcam \u003cstrong\u003eGeneral Multi-Unit\u003c\/strong\u003e cases. It seats in a printed model designed from an intraoral or lab scan, so the lab can check the framework's fit and contacts before delivery.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIncludes:\u003c\/strong\u003e 1 digital analog and 1 screw\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUse:\u003c\/strong\u003e 3D-printed models\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatible with:\u003c\/strong\u003e Surcam General Multi-Unit (M1.4)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAnalogs are lab-only parts and are never placed in the patient. For poured stone models, use the \u003ca href=\"https:\/\/surcamdental.shop\/products\/analog-general-multi-unit\"\u003elab analog for General Multi-Unit\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch2\u003eRelated parts\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/surcamdental.shop\/products\/scan-body-for-general-multi-unit\"\u003eGeneral Multi-Unit scan body\u003c\/a\u003e · \u003ca href=\"https:\/\/surcamdental.shop\/collections\/implant-analogs\"\u003eall implant analogs\u003c\/a\u003e · \u003ca href=\"https:\/\/surcamdental.shop\/pages\/digital-libraries\"\u003edigital libraries\u003c\/a\u003e\u003c\/p\u003e","brand":"Surcam","offers":[{"title":"Default Title","offer_id":39931826962497,"sku":"DASM-300146","price":18.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0558\/0180\/6913\/products\/DASM-300146.1_Shopify.jpg?v=1745938282"},{"product_id":"analog-standard-platform-ih-2-42","title":"Analog Standard Platform","description":"\u003ch2 data-start=\"27\" data-end=\"110\"\u003eInternal Hex 2.42 lab analog for precise CAD\/CAM model indexing \u0026amp; stable seating\u003c\/h2\u003e\n\u003cp data-start=\"136\" data-end=\"591\"\u003eThe \u003cstrong data-start=\"140\" data-end=\"175\"\u003eSurcam Analog Standard Platform\u003c\/strong\u003e is a precision \u003cstrong data-start=\"191\" data-end=\"212\"\u003elaboratory analog\u003c\/strong\u003e for \u003cstrong data-start=\"217\" data-end=\"241\"\u003eInternal Hex 2.42 mm\u003c\/strong\u003e implant systems. Machined from \u003cstrong data-start=\"273\" data-end=\"305\"\u003eTitanium Grade 5 (Ti-6Al-4V)\u003c\/strong\u003e, it replicates the implant connection in \u003cstrong data-start=\"347\" data-end=\"378\"\u003e3D-printed or milled models\u003c\/strong\u003e so labs can fabricate accurate \u003cstrong data-start=\"410\" data-end=\"464\"\u003escrew-retained single units and short-span bridges\u003c\/strong\u003e with predictable fit.\u003cbr data-start=\"486\" data-end=\"489\"\u003e\u003cstrong data-start=\"489\" data-end=\"502\"\u003eIncludes:\u003c\/strong\u003e 1× Standard Analog.\u003cbr data-start=\"522\" data-end=\"525\"\u003e\u003cstrong data-start=\"525\" data-end=\"543\"\u003eCompatibility:\u003c\/strong\u003e Internal Hex 2.42 platforms (verify interface).\u003c\/p\u003e\n\u003chr data-start=\"593\" data-end=\"596\"\u003e\n\u003ch2 data-start=\"598\" data-end=\"609\"\u003eBenefits\u003c\/h2\u003e\n\u003cul data-start=\"610\" data-end=\"1107\"\u003e\n\u003cli data-start=\"610\" data-end=\"718\"\u003e\n\u003cp data-start=\"612\" data-end=\"718\"\u003e\u003cstrong data-start=\"612\" data-end=\"630\"\u003eModel Accuracy\u003c\/strong\u003e — Tight tolerances support precise analog positioning for predictable prosthetic fit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"719\" data-end=\"825\"\u003e\n\u003cp data-start=\"721\" data-end=\"825\"\u003e\u003cstrong data-start=\"721\" data-end=\"739\"\u003eStable Seating\u003c\/strong\u003e — Geometry designed to seat securely in printed\/milled sockets and resist rotation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"826\" data-end=\"922\"\u003e\n\u003cp data-start=\"828\" data-end=\"922\"\u003e\u003cstrong data-start=\"828\" data-end=\"845\"\u003eCAD\/CAM Ready\u003c\/strong\u003e — Works seamlessly with IOS-to-CAD\/CAM workflows and common lab libraries.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"923\" data-end=\"1019\"\u003e\n\u003cp data-start=\"925\" data-end=\"1019\"\u003e\u003cstrong data-start=\"925\" data-end=\"945\"\u003eDurable Titanium\u003c\/strong\u003e — \u003cstrong data-start=\"948\" data-end=\"959\"\u003eGrade 5\u003c\/strong\u003e construction resists wear across repeated lab procedures.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1020\" data-end=\"1107\"\u003e\n\u003cp data-start=\"1022\" data-end=\"1107\"\u003e\u003cstrong data-start=\"1022\" data-end=\"1041\"\u003eBroad Ecosystem\u003c\/strong\u003e — Compatible with major \u003cstrong data-start=\"1066\" data-end=\"1077\"\u003eIH 2.42\u003c\/strong\u003e families (confirm interface).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1109\" data-end=\"1112\"\u003e\n\u003ch2 data-start=\"1114\" data-end=\"1132\"\u003eProduct Details\u003c\/h2\u003e\n\u003cul data-start=\"1133\" data-end=\"1488\"\u003e\n\u003cli data-start=\"1133\" data-end=\"1192\"\u003e\n\u003cp data-start=\"1135\" data-end=\"1192\"\u003e\u003cstrong data-start=\"1135\" data-end=\"1161\"\u003ePlatform \/ Connection:\u003c\/strong\u003e \u003cstrong data-start=\"1162\" data-end=\"1190\"\u003eInternal Hexagon 2.42 mm\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1193\" data-end=\"1243\"\u003e\n\u003cp data-start=\"1195\" data-end=\"1243\"\u003e\u003cstrong data-start=\"1195\" data-end=\"1208\"\u003eMaterial:\u003c\/strong\u003e \u003cstrong data-start=\"1209\" data-end=\"1241\"\u003eTitanium Grade 5 (Ti-6Al-4V)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1244\" data-end=\"1289\"\u003e\n\u003cp data-start=\"1246\" data-end=\"1289\"\u003e\u003cstrong data-start=\"1246\" data-end=\"1264\"\u003ePack Contents:\u003c\/strong\u003e \u003cstrong data-start=\"1265\" data-end=\"1287\"\u003e1× Standard Analog\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1290\" data-end=\"1417\"\u003e\n\u003cp data-start=\"1292\" data-end=\"1417\"\u003e\u003cstrong data-start=\"1292\" data-end=\"1316\"\u003eBrand Compatibility:\u003c\/strong\u003e \u003cstrong data-start=\"1317\" data-end=\"1331\"\u003eAlpha Bio®\u003c\/strong\u003e, \u003cstrong data-start=\"1333\" data-end=\"1344\"\u003eZimmer®\u003c\/strong\u003e, \u003cstrong data-start=\"1346\" data-end=\"1354\"\u003eMIS®\u003c\/strong\u003e, \u003cstrong data-start=\"1356\" data-end=\"1365\"\u003eAdin®\u003c\/strong\u003e, \u003cstrong data-start=\"1367\" data-end=\"1386\"\u003eImplant Direct®\u003c\/strong\u003e, \u003cstrong data-start=\"1388\" data-end=\"1402\"\u003eAB Dental®\u003c\/strong\u003e (verify fit)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1418\" data-end=\"1488\"\u003e\n\u003cp data-start=\"1420\" data-end=\"1488\"\u003e\u003cstrong data-start=\"1420\" data-end=\"1428\"\u003eUse:\u003c\/strong\u003e \u003cstrong data-start=\"1429\" data-end=\"1458\"\u003eLaboratory\/model use only\u003c\/strong\u003e (not for intraoral placement)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1490\" data-end=\"1493\"\u003e\n\u003ch2 data-start=\"1495\" data-end=\"1512\"\u003eSpecifications\u003c\/h2\u003e\n\u003cul data-start=\"1513\" data-end=\"1813\"\u003e\n\u003cli data-start=\"1513\" data-end=\"1582\"\u003e\n\u003cp data-start=\"1515\" data-end=\"1582\"\u003eDesigned for \u003cstrong data-start=\"1528\" data-end=\"1552\"\u003eintraoral-scan–based\u003c\/strong\u003e (IOS) restorative workflows\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1583\" data-end=\"1670\"\u003e\n\u003cp data-start=\"1585\" data-end=\"1670\"\u003eSeats into \u003cstrong data-start=\"1596\" data-end=\"1620\"\u003e3D-printed or milled\u003c\/strong\u003e model sockets; verify full seating and indexing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1671\" data-end=\"1745\"\u003e\n\u003cp data-start=\"1673\" data-end=\"1745\"\u003eFollow library parameters for \u003cstrong data-start=\"1703\" data-end=\"1724\"\u003esocket dimensions\u003c\/strong\u003e and \u003cstrong data-start=\"1729\" data-end=\"1743\"\u003etolerances\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1746\" data-end=\"1813\"\u003e\n\u003cp data-start=\"1748\" data-end=\"1813\"\u003eClean and inspect seating surfaces to maintain \u003cstrong data-start=\"1795\" data-end=\"1813\"\u003emodel accuracy\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1815\" data-end=\"1818\"\u003e\n\u003ch2 data-start=\"1820\" data-end=\"1849\"\u003eWhy Choose Surcam Analogs?\u003c\/h2\u003e\n\u003cul data-start=\"1850\" data-end=\"2038\"\u003e\n\u003cli data-start=\"1850\" data-end=\"1918\"\u003e\n\u003cp data-start=\"1852\" data-end=\"1918\"\u003eConsistent \u003cstrong data-start=\"1863\" data-end=\"1883\"\u003efit and indexing\u003c\/strong\u003e for accurate CAD\/CAM fabrication\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1919\" data-end=\"1979\"\u003e\n\u003cp data-start=\"1921\" data-end=\"1979\"\u003e\u003cstrong data-start=\"1921\" data-end=\"1941\"\u003eGrade 5 titanium\u003c\/strong\u003e longevity and dimensional stability\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1980\" data-end=\"2038\"\u003e\n\u003cp data-start=\"1982\" data-end=\"2038\"\u003eSmooth integration into modern \u003cstrong data-start=\"2013\" data-end=\"2038\"\u003edigital lab workflows\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2040\" data-end=\"2043\"\u003e\n\u003ch2 data-start=\"1820\" data-end=\"1849\"\u003eSurcam Analogs FAQs\u003c\/h2\u003e\n\u003ch3 data-start=\"2053\" data-end=\"2096\"\u003eWhich implant platforms are compatible?\u003c\/h3\u003e\n\u003cp data-start=\"2097\" data-end=\"2266\"\u003eInternal Hex \u003cstrong data-start=\"2110\" data-end=\"2121\"\u003e2.42 mm\u003c\/strong\u003e systems including \u003cstrong data-start=\"2140\" data-end=\"2205\"\u003eAlpha Bio®, Zimmer®, MIS®, Adin®, Implant Direct®, AB Dental®\u003c\/strong\u003e. Always verify platform dimensions and interface before use.\u003c\/p\u003e\n\u003ch3 data-start=\"2268\" data-end=\"2314\"\u003eIs this analog intended for intraoral use?\u003c\/h3\u003e\n\u003cp data-start=\"2315\" data-end=\"2405\"\u003eNo. It is \u003cstrong data-start=\"2325\" data-end=\"2337\"\u003elab-only\u003c\/strong\u003e, intended for printed\/milled models to support CAD\/CAM fabrication.\u003c\/p\u003e\n\u003ch3 data-start=\"2407\" data-end=\"2471\"\u003eDoes it work with 3D-printed models from different printers?\u003c\/h3\u003e\n\u003cp data-start=\"2472\" data-end=\"2585\"\u003eYes. It is \u003cstrong data-start=\"2483\" data-end=\"2503\"\u003eprinter-agnostic\u003c\/strong\u003e; ensure you use the correct analog library and that sockets are produced to spec.\u003c\/p\u003e\n\u003ch3 data-start=\"2587\" data-end=\"2630\"\u003eHow is the analog secured in the model?\u003c\/h3\u003e\n\u003cp data-start=\"2631\" data-end=\"2784\"\u003eSeat fully into the printed\/milled socket per your \u003cstrong data-start=\"2682\" data-end=\"2706\"\u003elibrary’s tolerances\u003c\/strong\u003e and lab protocol. Verify rotational index and full seating before proceeding.\u003c\/p\u003e\n\u003ch3 data-start=\"2786\" data-end=\"2832\"\u003eWhat types of restorations is it used for?\u003c\/h3\u003e\n\u003cp data-start=\"2833\" data-end=\"2933\"\u003e\u003cstrong data-start=\"2833\" data-end=\"2888\"\u003eScrew-retained single crowns and short-span bridges\u003c\/strong\u003e fabricated via CAD\/CAM from intraoral scans.\u003c\/p\u003e\n\u003cp data-start=\"2833\" data-end=\"2933\"\u003e*Trademark note: Alpha Bio®, Zimmer®, MIS®, Adin®, Implant Direct®, and AB Dental® are registered trademarks of their respective owners. References are for compatibility\/comparison only.\u003c\/p\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"FAQPage\",\n  \"inLanguage\": \"en\",\n  \"mainEntity\": [\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Which implant platforms are compatible?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Internal Hex 2.42 mm systems including Alpha Bio®, Zimmer®, MIS®, Adin®, Implant Direct®, and AB Dental®. Always verify platform dimensions and interface before use.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Is this analog intended for intraoral use?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"No. It is for laboratory use only in printed or milled models to support CAD\/CAM fabrication.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Does it work with 3D-printed models from different printers?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Yes. It is printer-agnostic. Use the correct analog library and ensure sockets are produced to specification for accurate seating and indexing.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"How is the analog secured in the model?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Seat the analog fully into the printed or milled socket according to your CAD\/CAM library tolerances and lab protocol. Verify rotational index and full seating before proceeding.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What types of restorations is it used for?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Screw-retained single crowns and short-span bridges fabricated via CAD\/CAM from intraoral scans.\"\n      }\n    }\n  ]\n}\n\u003c\/script\u003e\n","brand":"Surcam","offers":[{"title":"Default Title","offer_id":40311118659649,"sku":"AMS-1201","price":13.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0558\/0180\/6913\/products\/AMS-1201.1_Shopify.jpg?v=1653819412"},{"product_id":"angular-aesthetic-abutment-ih-2-42","title":"Angular Aesthetic Abutment","description":"\u003ch2\u003eAngled abutment for Internal Hex 2.42 - path correction, esthetic emergence \u0026amp; screw-retained access\u003c\/h2\u003e\n\u003cp data-start=\"157\" data-end=\"777\"\u003eThe \u003cstrong data-start=\"161\" data-end=\"198\"\u003eSurcam Angular Aesthetic Abutment\u003c\/strong\u003e corrects implant divergence to establish a predictable \u003cstrong data-start=\"254\" data-end=\"290\"\u003escrew-retained path of insertion\u003c\/strong\u003e while shaping a clean, natural \u003cstrong data-start=\"322\" data-end=\"343\"\u003eemergence profile\u003c\/strong\u003e. Precision-machined from \u003cstrong data-start=\"369\" data-end=\"401\"\u003eTitanium Grade 5 (Ti-6Al-4V)\u003c\/strong\u003e for strength and biocompatibility, it supports efficient chairside workflows and long-term serviceability through retrievable access.\u003cbr data-start=\"535\" data-end=\"538\"\u003e\u003cstrong data-start=\"538\" data-end=\"551\"\u003eIncludes:\u003c\/strong\u003e 1× Angular Abutment, 1× Prosthetic Screw.\u003cbr data-start=\"593\" data-end=\"596\"\u003e\u003cstrong data-start=\"596\" data-end=\"614\"\u003eCompatibility:\u003c\/strong\u003e \u003cstrong data-start=\"615\" data-end=\"639\"\u003eInternal Hex 2.42 mm\u003c\/strong\u003e platforms; families such as \u003cstrong data-start=\"668\" data-end=\"682\"\u003eAlpha Bio®\u003c\/strong\u003e, \u003cstrong data-start=\"684\" data-end=\"695\"\u003eZimmer®\u003c\/strong\u003e, \u003cstrong data-start=\"697\" data-end=\"705\"\u003eMIS®\u003c\/strong\u003e, \u003cstrong data-start=\"707\" data-end=\"716\"\u003eAdin®\u003c\/strong\u003e, \u003cstrong data-start=\"718\" data-end=\"737\"\u003eImplant Direct®\u003c\/strong\u003e, \u003cstrong data-start=\"739\" data-end=\"753\"\u003eAB Dental®\u003c\/strong\u003e (verify interface fit).\u003c\/p\u003e\n\u003chr data-start=\"779\" data-end=\"782\"\u003e\n\u003ch2 data-start=\"784\" data-end=\"795\"\u003eBenefits\u003c\/h2\u003e\n\u003cul data-start=\"796\" data-end=\"1286\"\u003e\n\u003cli data-start=\"796\" data-end=\"905\"\u003e\n\u003cp data-start=\"798\" data-end=\"905\"\u003e\u003cstrong data-start=\"798\" data-end=\"830\"\u003ePath Alignment \u0026amp; Parallelism\u003c\/strong\u003e — Angled design corrects divergence for passive, screw-retained seating.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"906\" data-end=\"1004\"\u003e\n\u003cp data-start=\"908\" data-end=\"1004\"\u003e\u003cstrong data-start=\"908\" data-end=\"931\"\u003eSoft-Tissue Support\u003c\/strong\u003e — Transmucosal contour promotes a hygienic, esthetic cervical profile.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1005\" data-end=\"1095\"\u003e\n\u003cp data-start=\"1007\" data-end=\"1095\"\u003e\u003cstrong data-start=\"1007\" data-end=\"1025\"\u003eRetrievability\u003c\/strong\u003e — Screw-retained restorations allow maintenance and hygiene access.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1096\" data-end=\"1191\"\u003e\n\u003cp data-start=\"1098\" data-end=\"1191\"\u003e\u003cstrong data-start=\"1098\" data-end=\"1122\"\u003eStrength \u0026amp; Precision\u003c\/strong\u003e — \u003cstrong data-start=\"1125\" data-end=\"1146\"\u003eTi-6Al-4V Grade 5\u003c\/strong\u003e with tight tolerances for stable indexing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1192\" data-end=\"1286\"\u003e\n\u003cp data-start=\"1194\" data-end=\"1286\"\u003e\u003cstrong data-start=\"1194\" data-end=\"1217\"\u003eWorkflow Efficiency\u003c\/strong\u003e — Streamlines impression\/CAD-CAM and delivery with reliable seating.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1288\" data-end=\"1291\"\u003e\n\u003ch2 data-start=\"1293\" data-end=\"1311\"\u003eProduct Details\u003c\/h2\u003e\n\u003cul data-start=\"1312\" data-end=\"1685\"\u003e\n\u003cli data-start=\"1312\" data-end=\"1371\"\u003e\n\u003cp data-start=\"1314\" data-end=\"1371\"\u003e\u003cstrong data-start=\"1314\" data-end=\"1340\"\u003eConnection \/ Platform:\u003c\/strong\u003e Internal Hexagon \u003cstrong data-start=\"1358\" data-end=\"1369\"\u003e2.42 mm\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1372\" data-end=\"1422\"\u003e\n\u003cp data-start=\"1374\" data-end=\"1422\"\u003e\u003cstrong data-start=\"1374\" data-end=\"1387\"\u003eMaterial:\u003c\/strong\u003e \u003cstrong data-start=\"1388\" data-end=\"1420\"\u003eTitanium Grade 5 (Ti-6Al-4V)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1423\" data-end=\"1512\"\u003e\n\u003cp data-start=\"1425\" data-end=\"1512\"\u003e\u003cstrong data-start=\"1425\" data-end=\"1448\"\u003eAngulation Options:\u003c\/strong\u003e Select angle variant per case plan (verify available options)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1513\" data-end=\"1576\"\u003e\n\u003cp data-start=\"1515\" data-end=\"1576\"\u003e\u003cstrong data-start=\"1515\" data-end=\"1533\"\u003ePack Contents:\u003c\/strong\u003e 1× Angular Abutment, 1× Prosthetic Screw\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1577\" data-end=\"1685\"\u003e\n\u003cp data-start=\"1579\" data-end=\"1685\"\u003e\u003cstrong data-start=\"1579\" data-end=\"1603\"\u003eBrand Compatibility:\u003c\/strong\u003e Alpha Bio®, Zimmer®, MIS®, Adin®, Implant Direct®, AB Dental® (confirm interface)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1687\" data-end=\"1690\"\u003e\n\u003ch2 data-start=\"1692\" data-end=\"1709\"\u003eSpecifications\u003c\/h2\u003e\n\u003cul data-start=\"1710\" data-end=\"2098\"\u003e\n\u003cli data-start=\"1710\" data-end=\"1813\"\u003e\n\u003cp data-start=\"1712\" data-end=\"1813\"\u003e\u003cstrong data-start=\"1712\" data-end=\"1728\"\u003eIndications:\u003c\/strong\u003e Screw-retained single crowns and short-span bridges; esthetic emergence management\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1814\" data-end=\"1913\"\u003e\n\u003cp data-start=\"1816\" data-end=\"1913\"\u003e\u003cstrong data-start=\"1816\" data-end=\"1832\"\u003eProsthetics:\u003c\/strong\u003e Compatible with conventional impressions and \u003cstrong data-start=\"1878\" data-end=\"1889\"\u003eCAD\/CAM\u003c\/strong\u003e workflows for IH 2.42\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1914\" data-end=\"2005\"\u003e\n\u003cp data-start=\"1916\" data-end=\"2005\"\u003e\u003cstrong data-start=\"1916\" data-end=\"1935\"\u003eSeating\/Torque:\u003c\/strong\u003e Seat fully; \u003cstrong data-start=\"1948\" data-end=\"1981\"\u003etorque per implant system IFU\u003c\/strong\u003e (do not exceed specs)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2006\" data-end=\"2098\"\u003e\n\u003cp data-start=\"2008\" data-end=\"2098\"\u003e\u003cstrong data-start=\"2008\" data-end=\"2020\"\u003eHygiene:\u003c\/strong\u003e Transmucosal geometry designed to facilitate plaque control around the margin\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2100\" data-end=\"2103\"\u003e\n\u003ch2 data-start=\"2105\" data-end=\"2144\"\u003eWhy Choose Surcam Angular Abutments?\u003c\/h2\u003e\n\u003cul data-start=\"2145\" data-end=\"2343\"\u003e\n\u003cli data-start=\"2145\" data-end=\"2209\"\u003e\n\u003cp data-start=\"2147\" data-end=\"2209\"\u003ePredictable \u003cstrong data-start=\"2159\" data-end=\"2178\"\u003epath correction\u003c\/strong\u003e on tilted\/divergent implants\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2210\" data-end=\"2280\"\u003e\n\u003cp data-start=\"2212\" data-end=\"2280\"\u003e\u003cstrong data-start=\"2212\" data-end=\"2227\"\u003eRetrievable\u003c\/strong\u003e screw-retained design for long-term serviceability\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2281\" data-end=\"2343\"\u003e\n\u003cp data-start=\"2283\" data-end=\"2343\"\u003e\u003cstrong data-start=\"2283\" data-end=\"2303\"\u003eGrade 5 titanium\u003c\/strong\u003e durability with precise, repeatable fit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2345\" data-end=\"2348\"\u003e\n\u003ch2 data-start=\"2350\" data-end=\"2357\"\u003eFAQs\u003c\/h2\u003e\n\u003ch3 data-start=\"2358\" data-end=\"2401\"\u003eWhich implant platforms are compatible?\u003c\/h3\u003e\n\u003cp data-start=\"2402\" data-end=\"2575\"\u003eInternal Hex \u003cstrong data-start=\"2415\" data-end=\"2426\"\u003e2.42 mm\u003c\/strong\u003e systems including \u003cstrong data-start=\"2445\" data-end=\"2510\"\u003eAlpha Bio®, Zimmer®, MIS®, Adin®, Implant Direct®, AB Dental®\u003c\/strong\u003e. Always verify platform dimensions and the interface before use.\u003c\/p\u003e\n\u003ch3 data-start=\"2577\" data-end=\"2612\"\u003eHow do I choose the angulation?\u003c\/h3\u003e\n\u003cp data-start=\"2613\" data-end=\"2797\"\u003eSelect the angle variant that corrects implant divergence and achieves a common path of insertion for \u003cstrong data-start=\"2715\" data-end=\"2742\"\u003epassive, screw-retained\u003c\/strong\u003e seating based on clinical and radiographic assessment.\u003c\/p\u003e\n\u003ch3 data-start=\"2799\" data-end=\"2852\"\u003eIs this abutment suitable for anterior esthetics?\u003c\/h3\u003e\n\u003cp data-start=\"2853\" data-end=\"3029\"\u003eYes. The transmucosal contour supports soft-tissue architecture and an esthetic emergence profile in anterior and premolar sites when paired with appropriate prosthetic design.\u003c\/p\u003e\n\u003ch3 data-start=\"3031\" data-end=\"3097\"\u003eWhat torque should I use for seating and the prosthetic screw?\u003c\/h3\u003e\n\u003cp data-start=\"3098\" data-end=\"3203\"\u003eFollow the \u003cstrong data-start=\"3109\" data-end=\"3133\"\u003eimplant system’s IFU\u003c\/strong\u003e for IH 2.42 torque values; do not exceed manufacturer specifications.\u003c\/p\u003e\n\u003ch3 data-start=\"3205\" data-end=\"3240\"\u003eIs a prosthetic screw included?\u003c\/h3\u003e\n\u003cp data-start=\"3241\" data-end=\"3287\"\u003eYes, each pack includes \u003cstrong data-start=\"3264\" data-end=\"3286\"\u003e1 prosthetic screw\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"3241\" data-end=\"3287\"\u003e*Trademark note: Alpha Bio®, Zimmer®, MIS®, Adin®, Implant Direct®, and AB Dental® are registered trademarks of their respective owners. References are for compatibility\/comparison only.\u003c\/p\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"FAQPage\",\n  \"inLanguage\": \"en\",\n  \"mainEntity\": [\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Which implant platforms are compatible?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Internal Hex 2.42 mm systems including Alpha Bio®, Zimmer®, MIS®, Adin®, Implant Direct®, and AB Dental®. Always verify platform dimensions and the interface before clinical use.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"How do I choose the angulation?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Select the angle variant that corrects implant divergence and creates a common path of insertion for passive, screw-retained seating based on clinical and radiographic assessment.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Is this abutment suitable for anterior esthetics?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Yes. The transmucosal contour supports soft-tissue architecture and an esthetic emergence profile in anterior and premolar sites when paired with appropriate prosthetic design.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What torque should be used for seating and the prosthetic screw?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Apply torque according to the implant system’s IFU for Internal Hex 2.42 platforms. Do not exceed manufacturer specifications.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Is a prosthetic screw included?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Yes. Each pack includes one prosthetic screw.\"\n      }\n    }\n  ]\n}\n\u003c\/script\u003e\n","brand":"Surcam","offers":[{"title":"15° Deg \/ 1.0 mm","offer_id":39931992113217,"sku":"ACM-1115-10","price":18.0,"currency_code":"USD","in_stock":true},{"title":"15° Deg \/ 2.0 mm","offer_id":40047809986625,"sku":"ACM-1215-20","price":18.0,"currency_code":"USD","in_stock":true},{"title":"15° Deg \/ 3.0 mm","offer_id":40047810019393,"sku":"ACM-1215-30","price":18.0,"currency_code":"USD","in_stock":true},{"title":"15° Deg \/ 4.0 mm","offer_id":40047810052161,"sku":"ACM-1315-40","price":18.0,"currency_code":"USD","in_stock":true},{"title":"25° Deg \/ 1.0 mm","offer_id":39932024062017,"sku":"ACM-1125-10","price":18.0,"currency_code":"USD","in_stock":true},{"title":"25° Deg \/ 2.0 mm","offer_id":40047810084929,"sku":"ACM-1225-20","price":18.0,"currency_code":"USD","in_stock":true},{"title":"25° Deg \/ 3.0 mm","offer_id":40047810117697,"sku":"ACM-1325-30","price":18.0,"currency_code":"USD","in_stock":true},{"title":"25° Deg \/ 4.0 mm","offer_id":40047810150465,"sku":"ACM-1425-40","price":18.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0558\/0180\/6913\/files\/ACM-15_All_Shopify.jpg?v=1750084915"},{"product_id":"np-angular-multi-unit","title":"Angular Multi-Unit NP","description":"\u003ch2 data-start=\"33\" data-end=\"122\"\u003eAngled NP 3.5 Multi-Unit Abutment for Screw-Retained Full-Arch \u0026amp; Divergence Correction\u003c\/h2\u003e\n\u003cp data-start=\"147\" data-end=\"873\"\u003eThe \u003cstrong data-start=\"151\" data-end=\"192\"\u003eSurcam NP Platform Angular Multi-Unit\u003c\/strong\u003e is a low-profile, \u003cstrong data-start=\"211\" data-end=\"240\"\u003econical-connection NP 3.5\u003c\/strong\u003e abutment system for \u003cstrong data-start=\"261\" data-end=\"290\"\u003escrew-retained prostheses\u003c\/strong\u003e—ideal when implants are \u003cstrong data-start=\"315\" data-end=\"325\"\u003etilted\u003c\/strong\u003e or divergent. Precision-machined from \u003cstrong data-start=\"364\" data-end=\"396\"\u003eTitanium Grade 5 (Ti-6Al-4V)\u003c\/strong\u003e, it aligns the restorative path of insertion, improves cleansability, and supports predictable full-arch and segmental restorations. Available in \u003cstrong data-start=\"543\" data-end=\"579\"\u003estraight (0°), 17°, 30°, and 45°\u003c\/strong\u003e with a range of \u003cstrong data-start=\"596\" data-end=\"616\"\u003egingival heights\u003c\/strong\u003e for soft-tissue adaptation.\u003cbr data-start=\"644\" data-end=\"647\"\u003e\u003cstrong data-start=\"647\" data-end=\"660\"\u003eIncludes:\u003c\/strong\u003e 1× Angular Conical Platform Multi-Unit, 1× Prosthetic Screw, 1× Stick Holder.\u003cbr data-start=\"738\" data-end=\"741\"\u003e\u003cstrong data-start=\"741\" data-end=\"759\"\u003eCompatibility:\u003c\/strong\u003e \u003cstrong data-start=\"760\" data-end=\"789\"\u003eConical Connection NP 3.5\u003c\/strong\u003e platform; \u003cstrong data-start=\"800\" data-end=\"817\"\u003eNobel Active®\u003c\/strong\u003e compatible (verify interface and platform before use).*\u003c\/p\u003e\n\u003chr data-start=\"875\" data-end=\"878\"\u003e\n\u003ch2 data-start=\"880\" data-end=\"891\"\u003eBenefits\u003c\/h2\u003e\n\u003cul data-start=\"892\" data-end=\"1640\"\u003e\n\u003cli data-start=\"892\" data-end=\"1017\"\u003e\n\u003cp data-start=\"894\" data-end=\"1017\"\u003e\u003cstrong data-start=\"894\" data-end=\"919\"\u003eDivergence Correction\u003c\/strong\u003e — 0°\/17°\/30°\/45° options align the prosthetic pathway for passive, screw-retained restorations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1018\" data-end=\"1115\"\u003e\n\u003cp data-start=\"1020\" data-end=\"1115\"\u003e\u003cstrong data-start=\"1020\" data-end=\"1045\"\u003eLow-Profile Emergence\u003c\/strong\u003e — Enhances hygiene access and esthetics under full-arch frameworks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1116\" data-end=\"1220\"\u003e\n\u003cp data-start=\"1118\" data-end=\"1220\"\u003e\u003cstrong data-start=\"1118\" data-end=\"1151\"\u003eScrew-Retained Retrievability\u003c\/strong\u003e — Easy access for maintenance, hygiene, and component replacement.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1221\" data-end=\"1323\"\u003e\n\u003cp data-start=\"1223\" data-end=\"1323\"\u003e\u003cstrong data-start=\"1223\" data-end=\"1249\"\u003eSoft-Tissue Adaptation\u003c\/strong\u003e — Multiple \u003cstrong data-start=\"1261\" data-end=\"1281\"\u003egingival heights\u003c\/strong\u003e to match biotype and mucosal thickness.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1324\" data-end=\"1436\"\u003e\n\u003cp data-start=\"1326\" data-end=\"1436\"\u003e\u003cstrong data-start=\"1326\" data-end=\"1347\"\u003eChairside Control\u003c\/strong\u003e — \u003cstrong data-start=\"1350\" data-end=\"1366\"\u003eStick holder\u003c\/strong\u003e improves handling and visibility in posterior\/limited access sites.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1437\" data-end=\"1541\"\u003e\n\u003cp data-start=\"1439\" data-end=\"1541\"\u003e\u003cstrong data-start=\"1439\" data-end=\"1462\"\u003eMaterial Confidence\u003c\/strong\u003e — \u003cstrong data-start=\"1465\" data-end=\"1486\"\u003eTi-6Al-4V Grade 5\u003c\/strong\u003e strength and biocompatibility for long-term service.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1542\" data-end=\"1640\"\u003e\n\u003cp data-start=\"1544\" data-end=\"1640\"\u003e\u003cstrong data-start=\"1544\" data-end=\"1563\"\u003eFull-Arch Ready\u003c\/strong\u003e — Supports \u003cstrong data-start=\"1575\" data-end=\"1587\"\u003eAll-on-X\u003c\/strong\u003e concepts (case-dependent) with cross-arch splinting.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1642\" data-end=\"1645\"\u003e\n\u003ch2 data-start=\"1647\" data-end=\"1665\"\u003eProduct Details\u003c\/h2\u003e\n\u003cul data-start=\"1666\" data-end=\"2087\"\u003e\n\u003cli data-start=\"1666\" data-end=\"1726\"\u003e\n\u003cp data-start=\"1668\" data-end=\"1726\"\u003e\u003cstrong data-start=\"1668\" data-end=\"1694\"\u003eConnection \/ Platform:\u003c\/strong\u003e Conical connection \u003cstrong data-start=\"1714\" data-end=\"1724\"\u003eNP 3.5\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1727\" data-end=\"1776\"\u003e\n\u003cp data-start=\"1729\" data-end=\"1776\"\u003e\u003cstrong data-start=\"1729\" data-end=\"1752\"\u003eAngulation Options:\u003c\/strong\u003e \u003cstrong data-start=\"1753\" data-end=\"1774\"\u003e0°, 17°, 30°, 45°\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1777\" data-end=\"1859\"\u003e\n\u003cp data-start=\"1779\" data-end=\"1859\"\u003e\u003cstrong data-start=\"1779\" data-end=\"1800\"\u003eGingival Heights:\u003c\/strong\u003e Multiple options (select per tissue thickness\/esthetics)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1860\" data-end=\"1910\"\u003e\n\u003cp data-start=\"1862\" data-end=\"1910\"\u003e\u003cstrong data-start=\"1862\" data-end=\"1875\"\u003eMaterial:\u003c\/strong\u003e \u003cstrong data-start=\"1876\" data-end=\"1908\"\u003eTitanium Grade 5 (Ti-6Al-4V)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1911\" data-end=\"2005\"\u003e\n\u003cp data-start=\"1913\" data-end=\"2005\"\u003e\u003cstrong data-start=\"1913\" data-end=\"1931\"\u003ePack Contents:\u003c\/strong\u003e \u003cstrong data-start=\"1932\" data-end=\"1957\"\u003e1× Angular Multi-Unit\u003c\/strong\u003e, \u003cstrong data-start=\"1959\" data-end=\"1982\"\u003e1× Prosthetic Screw\u003c\/strong\u003e, \u003cstrong data-start=\"1984\" data-end=\"2003\"\u003e1× Stick Holder\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2006\" data-end=\"2087\"\u003e\n\u003cp data-start=\"2008\" data-end=\"2087\"\u003e\u003cstrong data-start=\"2008\" data-end=\"2032\"\u003eBrand Compatibility:\u003c\/strong\u003e \u003cstrong data-start=\"2033\" data-end=\"2050\"\u003eNobel Active®\u003c\/strong\u003e NP 3.5 (for comparison; confirm fit)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2089\" data-end=\"2092\"\u003e\n\u003ch2 data-start=\"2094\" data-end=\"2111\"\u003eSpecifications\u003c\/h2\u003e\n\u003cul data-start=\"2112\" data-end=\"2611\"\u003e\n\u003cli data-start=\"2112\" data-end=\"2218\"\u003e\n\u003cp data-start=\"2114\" data-end=\"2218\"\u003e\u003cstrong data-start=\"2114\" data-end=\"2130\"\u003eIndications:\u003c\/strong\u003e Screw-retained single, segmental, and full-arch prostheses on NP 3.5 conical implants\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2219\" data-end=\"2322\"\u003e\n\u003cp data-start=\"2221\" data-end=\"2322\"\u003e\u003cstrong data-start=\"2221\" data-end=\"2234\"\u003eWorkflow:\u003c\/strong\u003e Supports immediate provisionalization \u003cstrong data-start=\"2273\" data-end=\"2320\"\u003ewhen primary stability and occlusion permit\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2323\" data-end=\"2412\"\u003e\n\u003cp data-start=\"2325\" data-end=\"2412\"\u003e\u003cstrong data-start=\"2325\" data-end=\"2336\"\u003eTorque:\u003c\/strong\u003e Seat\/torque per implant system \u003cstrong data-start=\"2368\" data-end=\"2375\"\u003eIFU\u003c\/strong\u003e; do not exceed manufacturer values\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2413\" data-end=\"2532\"\u003e\n\u003cp data-start=\"2415\" data-end=\"2532\"\u003e\u003cstrong data-start=\"2415\" data-end=\"2431\"\u003eProsthetics:\u003c\/strong\u003e Use compatible multi-unit cylinders, temporary cylinders, and prosthetic screws per system library\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2533\" data-end=\"2611\"\u003e\n\u003cp data-start=\"2535\" data-end=\"2611\"\u003e\u003cstrong data-start=\"2535\" data-end=\"2547\"\u003eHygiene:\u003c\/strong\u003e Low-profile design facilitates plaque control around the collar\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2613\" data-end=\"2616\"\u003e\n\u003ch2 data-start=\"2618\" data-end=\"2650\"\u003eWhy Choose Surcam Multi-Unit?\u003c\/h2\u003e\n\u003cul data-start=\"2651\" data-end=\"2930\"\u003e\n\u003cli data-start=\"2651\" data-end=\"2714\"\u003e\n\u003cp data-start=\"2653\" data-end=\"2714\"\u003ePredictable \u003cstrong data-start=\"2665\" data-end=\"2683\"\u003epath alignment\u003c\/strong\u003e on tilted\/divergent implants\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2715\" data-end=\"2790\"\u003e\n\u003cp data-start=\"2717\" data-end=\"2790\"\u003e\u003cstrong data-start=\"2717\" data-end=\"2732\"\u003eRetrievable\u003c\/strong\u003e screw-retained prosthetics for long-term serviceability\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2791\" data-end=\"2861\"\u003e\n\u003cp data-start=\"2793\" data-end=\"2861\"\u003e\u003cstrong data-start=\"2793\" data-end=\"2812\"\u003eRobust titanium\u003c\/strong\u003e construction with precise machining tolerances\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2862\" data-end=\"2930\"\u003e\n\u003cp data-start=\"2864\" data-end=\"2930\"\u003eFull ecosystem support with \u003cstrong data-start=\"2892\" data-end=\"2920\"\u003ecomplementary components\u003c\/strong\u003e and sizes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2932\" data-end=\"2935\"\u003e\n\u003ch2 data-start=\"2618\" data-end=\"2650\"\u003eSurcam Multi-Unit FAQs\u003c\/h2\u003e\n\u003ch3 data-start=\"2945\" data-end=\"3000\"\u003eWhich platforms is this Multi-Unit compatible with?\u003c\/h3\u003e\n\u003cp data-start=\"3001\" data-end=\"3150\"\u003eConical Connection \u003cstrong data-start=\"3020\" data-end=\"3030\"\u003eNP 3.5\u003c\/strong\u003e platforms; \u003cstrong data-start=\"3042\" data-end=\"3066\"\u003eNobel Active® NP 3.5\u003c\/strong\u003e compatible. Always verify platform dimensions and the conical interface before use.\u003c\/p\u003e\n\u003ch3 data-start=\"3152\" data-end=\"3208\"\u003eWhich angulations are available and how do I choose?\u003c\/h3\u003e\n\u003cp data-start=\"3209\" data-end=\"3358\"\u003e\u003cstrong data-start=\"3209\" data-end=\"3230\"\u003e0°, 17°, 30°, 45°\u003c\/strong\u003e. Select the angle that corrects implant divergence and achieves a common path of insertion for passive, screw-retained seating.\u003c\/p\u003e\n\u003ch3 data-start=\"3360\" data-end=\"3400\"\u003eHow do I select the gingival height?\u003c\/h3\u003e\n\u003cp data-start=\"3401\" data-end=\"3538\"\u003eMatch the \u003cstrong data-start=\"3411\" data-end=\"3430\"\u003egingival height\u003c\/strong\u003e to soft-tissue thickness and intended emergence profile; confirm clinically (probing) and radiographically.\u003c\/p\u003e\n\u003ch3 data-start=\"3540\" data-end=\"3583\"\u003eCan this be used for immediate loading?\u003c\/h3\u003e\n\u003cp data-start=\"3584\" data-end=\"3722\"\u003eOften \u003cstrong data-start=\"3590\" data-end=\"3608\"\u003ecase-dependent\u003c\/strong\u003e. Immediate provisionalization requires adequate insertion torque, cross-arch splinting, and controlled occlusion.\u003c\/p\u003e\n\u003ch3 data-start=\"3724\" data-end=\"3790\"\u003eWhat torque should I use for seating and the prosthetic screw?\u003c\/h3\u003e\n\u003cp data-start=\"3791\" data-end=\"3906\"\u003eFollow the \u003cstrong data-start=\"3802\" data-end=\"3826\"\u003eimplant system’s IFU\u003c\/strong\u003e for NP 3.5 multi-unit torque values. Do not exceed manufacturer specifications.\u003c\/p\u003e\n\u003ch3 data-start=\"3908\" data-end=\"3944\"\u003eWhat is included in the package?\u003c\/h3\u003e\n\u003cp data-start=\"3945\" data-end=\"4053\"\u003e\u003cstrong data-start=\"3945\" data-end=\"3970\"\u003e1× Angular Multi-Unit\u003c\/strong\u003e, \u003cstrong data-start=\"3972\" data-end=\"3995\"\u003e1× Prosthetic Screw\u003c\/strong\u003e, and \u003cstrong data-start=\"4001\" data-end=\"4020\"\u003e1× Stick Holder\u003c\/strong\u003e for improved intraoral handling.\u003c\/p\u003e\n\u003cp data-start=\"4055\" data-end=\"4169\"\u003e* \u003cstrong data-start=\"4058\" data-end=\"4075\"\u003eNobel Active®\u003c\/strong\u003e is a registered trademark of Nobel Biocare. References are for compatibility\/comparison only.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Surcam","offers":[{"title":"17° Deg \/ 2.5 mm","offer_id":39959017652289,"sku":"MUN-300099","price":55.0,"currency_code":"USD","in_stock":true},{"title":"17° Deg \/ 3.5 mm","offer_id":42845536878657,"sku":"MUN-300061","price":55.0,"currency_code":"USD","in_stock":true},{"title":"30° Deg \/ 3.5 mm","offer_id":42845536911425,"sku":"MUN-300063","price":55.0,"currency_code":"USD","in_stock":true},{"title":"30° Deg \/ 4.5 mm","offer_id":42845536944193,"sku":"MUN-300100","price":55.0,"currency_code":"USD","in_stock":true},{"title":"45° Deg \/ 4.5 mm","offer_id":42845536976961,"sku":"MUN-300096","price":55.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0558\/0180\/6913\/products\/MUN-300099.1_Shopify_7ebebd78-5764-4658-a896-4c37c8f8655e.jpg?v=1658177654"},{"product_id":"straight-titanium-abutment-nobel-active-np-3-5","title":"Straight Titanium Abutment NP 3.5 (Nobel Active® Compatible)","description":"\u003cp data-start=\"1988\" data-end=\"2321\"\u003eThe \u003cstrong data-start=\"1992\" data-end=\"2055\"\u003eStraight Titanium Abutment NP 3.5 (Nobel Active compatible)\u003c\/strong\u003e supports predictable cement-retained restorations on \u003cstrong data-start=\"2109\" data-end=\"2138\"\u003econical connection NP 3.5\u003c\/strong\u003e platforms. Its \u003cstrong data-start=\"2154\" data-end=\"2168\"\u003eActive Hex\u003c\/strong\u003e indexing provides anti-rotation and precise orientation, while the \u003cstrong data-start=\"2236\" data-end=\"2259\"\u003eTi-6Al-4V (Grade 5)\u003c\/strong\u003e body delivers strength, biocompatibility, and stable margins.\u003c\/p\u003e\n\u003cp data-start=\"2323\" data-end=\"2341\"\u003e\u003cstrong data-start=\"2323\" data-end=\"2339\"\u003eClinical use\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"2342\" data-end=\"2671\"\u003e\n\u003cli data-start=\"2342\" data-end=\"2453\"\u003e\n\u003cp data-start=\"2344\" data-end=\"2453\"\u003eIndicated for single units or short-span bridges where a straight, cement-retained solution is appropriate.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2454\" data-end=\"2549\"\u003e\n\u003cp data-start=\"2456\" data-end=\"2549\"\u003eGingival heights \u003cstrong data-start=\"2473\" data-end=\"2483\"\u003e1.5 mm\u003c\/strong\u003e and \u003cstrong data-start=\"2488\" data-end=\"2498\"\u003e3.0 mm\u003c\/strong\u003e to match sulcus depth and soft-tissue thickness.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2550\" data-end=\"2618\"\u003e\n\u003cp data-start=\"2552\" data-end=\"2618\"\u003eSupplied with a matched \u003cstrong data-start=\"2576\" data-end=\"2596\"\u003eprosthetic screw\u003c\/strong\u003e for secure seating.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2619\" data-end=\"2671\"\u003e\n\u003cp data-start=\"2621\" data-end=\"2671\"\u003eCompatible with conventional or digital workflows.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003csection aria-labelledby=\"faqs\" class=\"product-faqs\"\u003e\n\u003carticle\u003e\n\u003ch2 data-start=\"3165\" data-end=\"3372\"\u003e\u003cstrong data-start=\"3165\" data-end=\"3222\"\u003eFAQs\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3 data-start=\"3165\" data-end=\"3372\"\u003e\u003cstrong data-start=\"3165\" data-end=\"3222\"\u003eIs this abutment compatible with Nobel Active NP 3.5?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-start=\"3165\" data-end=\"3372\"\u003eYes. It is designed for \u003cstrong data-start=\"3249\" data-end=\"3278\"\u003econical connection NP 3.5\u003c\/strong\u003e platforms with \u003cstrong data-start=\"3294\" data-end=\"3308\"\u003eActive Hex\u003c\/strong\u003e indexing. Always verify the platform code and index before use.\u003c\/p\u003e\n\u003ch3 data-start=\"3374\" data-end=\"3579\"\u003e\u003cstrong data-start=\"3374\" data-end=\"3414\"\u003eHow do I choose the gingival height?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-start=\"3374\" data-end=\"3579\"\u003eSelect \u003cstrong data-start=\"3424\" data-end=\"3437\"\u003eGH 1.5 mm\u003c\/strong\u003e for shallow sulcus or thin tissue, and \u003cstrong data-start=\"3477\" data-end=\"3490\"\u003eGH 3.0 mm\u003c\/strong\u003e for thicker tissue. Base selection on measured sulcus depth and desired margin position.\u003c\/p\u003e\n\u003ch3 data-start=\"3581\" data-end=\"3765\"\u003e\u003cstrong data-start=\"3581\" data-end=\"3653\"\u003eIs this abutment for screw-retained or cement-retained restorations?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-start=\"3581\" data-end=\"3765\"\u003eCement-retained. Use suitable provisional or definitive cement and remove excess according to best practices.\u003c\/p\u003e\n\u003ch3 data-start=\"3767\" data-end=\"3915\"\u003e\u003cstrong data-start=\"3767\" data-end=\"3807\"\u003eWhat torque and driver should I use?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-start=\"3767\" data-end=\"3915\"\u003eFollow the \u003cstrong data-start=\"3821\" data-end=\"3843\"\u003eimplant system IFU\u003c\/strong\u003e for the correct prosthetic screw torque and driver. Do not over-torque.\u003c\/p\u003e\n\u003ch3 data-start=\"3917\" data-end=\"4124\"\u003e\u003cstrong data-start=\"3917\" data-end=\"3953\"\u003eCan it be sterilized and reused?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-start=\"3917\" data-end=\"4124\"\u003eFollow the label and IFU. If supplied non-sterile, clean and \u003cstrong data-start=\"4017\" data-end=\"4036\"\u003esteam-sterilize\u003c\/strong\u003e before use. Abutments are \u003cstrong data-start=\"4063\" data-end=\"4085\"\u003esingle-patient use\u003c\/strong\u003e; replace the screw if worn or damaged.\u003c\/p\u003e\n\u003c\/article\u003e\n\u003c\/section\u003e","brand":"Surcam","offers":[{"title":"1.5mm","offer_id":39959258136641,"sku":"PD-300084","price":15.0,"currency_code":"USD","in_stock":true},{"title":"3.0mm","offer_id":39959258169409,"sku":"PD-300115","price":15.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0558\/0180\/6913\/files\/straight_titanium_abutment_NP_3.5_Nobel_Active_compatible.jpg?v=1757827826"},{"product_id":"long-digital-scan-body-internal-hex-2-42","title":"Long Digital Scan Body","description":"\u003cp data-start=\"429\" data-end=\"992\"\u003eThe \u003cstrong data-start=\"433\" data-end=\"466\"\u003eSurcam Long Digital Scan Body\u003c\/strong\u003e is a precision \u003cstrong data-start=\"482\" data-end=\"495\"\u003eTi-6Al-4V\u003c\/strong\u003e scan abutment engineered to enhance \u003cstrong data-start=\"532\" data-end=\"554\"\u003eintraoral scanning\u003c\/strong\u003e where restorative platforms sit \u003cstrong data-start=\"587\" data-end=\"607\"\u003edeep subgingival\u003c\/strong\u003e or in \u003cstrong data-start=\"614\" data-end=\"635\"\u003ethick soft tissue\u003c\/strong\u003e. The increased vertical height improves scanner visibility and landmark detection, helping CAD software register \u003cstrong data-start=\"749\" data-end=\"793\"\u003eimplant position, depth, and orientation\u003c\/strong\u003e reliably. Delivered with a \u003cstrong data-start=\"821\" data-end=\"841\"\u003eprosthetic screw\u003c\/strong\u003e for stable seating during scanning. Use with the appropriate digital libraries and follow your implant system IFU for torque\/driver and sterilization.\u003c\/p\u003e\n\u003cp data-start=\"994\" data-end=\"1238\"\u003e\u003cstrong data-start=\"994\" data-end=\"1007\"\u003eIncludes:\u003c\/strong\u003e 1× \u003cstrong data-start=\"1011\" data-end=\"1040\"\u003eLong Scan Body (Titanium)\u003c\/strong\u003e, 1× \u003cstrong data-start=\"1045\" data-end=\"1065\"\u003eProsthetic Screw\u003c\/strong\u003e\u003cbr data-start=\"1065\" data-end=\"1068\"\u003e\u003cstrong data-start=\"1068\" data-end=\"1094\"\u003eConnection \/ Platform:\u003c\/strong\u003e \u003cstrong data-start=\"1095\" data-end=\"1119\"\u003eInternal Hex 2.42 mm\u003c\/strong\u003e\u003cbr data-start=\"1119\" data-end=\"1122\"\u003e\u003cstrong data-start=\"1122\" data-end=\"1172\"\u003eBrand compatibility (third-party; verify fit):\u003c\/strong\u003e \u003cstrong data-start=\"1173\" data-end=\"1238\"\u003eAlpha-Bio®, Zimmer®, MIS®, Adin®, Implant Direct®, AB Dental®\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch2 data-start=\"2732\" data-end=\"2739\"\u003eFAQs\u003c\/h2\u003e\n\u003ch3 data-start=\"2741\" data-end=\"2805\"\u003eIs this scan body compatible with Internal Hex 2.42 systems?\u003c\/h3\u003e\n\u003cp data-start=\"2806\" data-end=\"2962\"\u003eDesigned for \u003cstrong data-start=\"2819\" data-end=\"2843\"\u003eInternal Hex 2.42 mm\u003c\/strong\u003e platforms used by Alpha-Bio, Zimmer, MIS, Adin, Implant Direct, and AB Dental. Always verify interface\/fit before use.\u003c\/p\u003e\n\u003ch3 data-start=\"2964\" data-end=\"3010\"\u003eWhen should I choose the \u003cstrong data-start=\"2993\" data-end=\"3001\"\u003eLong\u003c\/strong\u003e version?\u003c\/h3\u003e\n\u003cp data-start=\"3011\" data-end=\"3170\"\u003eSelect \u003cstrong data-start=\"3018\" data-end=\"3026\"\u003eLong\u003c\/strong\u003e for \u003cstrong data-start=\"3031\" data-end=\"3086\"\u003edeep platforms, thick soft tissue, posterior access\u003c\/strong\u003e, or whenever extra vertical height improves scanner capture and landmark detection.\u003c\/p\u003e\n\u003ch3 data-start=\"3172\" data-end=\"3214\"\u003eWhich digital libraries are supported?\u003c\/h3\u003e\n\u003cp data-start=\"3215\" data-end=\"3366\"\u003eUse the corresponding \u003cstrong data-start=\"3237\" data-end=\"3257\"\u003eSurcam libraries\u003c\/strong\u003e for your CAD system (e.g., 3Shape, exocad, Dental Wings where available). Contact support if you need files.\u003c\/p\u003e\n\u003ch3 data-start=\"3368\" data-end=\"3426\"\u003eHow tight should I fasten it and can it be sterilized?\u003c\/h3\u003e\n\u003cp data-start=\"3427\" data-end=\"3591\"\u003eFollow your \u003cstrong data-start=\"3439\" data-end=\"3461\"\u003eimplant system IFU\u003c\/strong\u003e for driver type and (low) torque used during scanning. If supplied non-sterile, \u003cstrong data-start=\"3542\" data-end=\"3571\"\u003eclean and steam-sterilize\u003c\/strong\u003e per IFU before use.\u003c\/p\u003e\n\u003ch3 data-start=\"3593\" data-end=\"3625\"\u003eWhat’s included in the pack?\u003c\/h3\u003e\n\u003cp data-start=\"3626\" data-end=\"3685\"\u003e\u003cstrong data-start=\"3626\" data-end=\"3656\"\u003e1× Long titanium scan body\u003c\/strong\u003e and \u003cstrong data-start=\"3661\" data-end=\"3684\"\u003e1× prosthetic screw\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Surcam","offers":[{"title":"Default Title","offer_id":40015015116865,"sku":"SBT-100056","price":20.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0558\/0180\/6913\/products\/long_titanium_digital_scan_body_internal_hex_2.42.jpg?v=1757855601"},{"product_id":"angular-titanium-abutment-nobel-active-np-3-5","title":"Angular Titanium Abutment NP 3.5 (Nobel Active® Compatible)","description":"\u003cp\u003eThe \u003cstrong data-start=\"2120\" data-end=\"2182\"\u003eAngular Titanium Abutment NP 3.5 (Nobel Active compatible)\u003c\/strong\u003e provides a precise, cement-retained solution when correction of implant angulation is required. The \u003cstrong data-start=\"2283\" data-end=\"2297\"\u003eActive Hex\u003c\/strong\u003e index supports stable orientation and anti-rotation, while \u003cstrong data-start=\"2357\" data-end=\"2380\"\u003eTi-6Al-4V (Grade 5)\u003c\/strong\u003e delivers strength and biocompatibility. Choose \u003cstrong data-start=\"2428\" data-end=\"2442\"\u003e15° \u003c\/strong\u003eangulation and \u003cstrong data-start=\"2458\" data-end=\"2481\"\u003eGH 1.5 mm or 3.0 mm\u003c\/strong\u003e to match tissue thickness and emergence. Supplied with a matched \u003cstrong data-start=\"2547\" data-end=\"2567\"\u003eprosthetic screw\u003c\/strong\u003e. Suitable for single units or short-span bridges within conical \u003cstrong data-start=\"2632\" data-end=\"2642\"\u003eNP 3.5\u003c\/strong\u003e platforms.\u003c\/p\u003e\n\u003ch2 data-start=\"0\" data-end=\"7\"\u003eFAQs\u003c\/h2\u003e\n\u003ch3 data-start=\"9\" data-end=\"66\"\u003eIs this abutment compatible with Nobel Active NP 3.5?\u003c\/h3\u003e\n\u003cp data-start=\"67\" data-end=\"214\"\u003eYes. It is designed for conical connection \u003cstrong data-start=\"110\" data-end=\"120\"\u003eNP 3.5\u003c\/strong\u003e platforms with \u003cstrong data-start=\"136\" data-end=\"150\"\u003eActive Hex\u003c\/strong\u003e indexing. Always verify the platform code and index before use.\u003c\/p\u003e\n\u003ch3 data-start=\"216\" data-end=\"261\"\u003eHow do I choose the gingival height (GH)?\u003c\/h3\u003e\n\u003cp data-start=\"262\" data-end=\"420\"\u003eSelect \u003cstrong data-start=\"269\" data-end=\"282\"\u003eGH 1.5 mm\u003c\/strong\u003e for shallow sulcus\/thin tissue and \u003cstrong data-start=\"318\" data-end=\"331\"\u003eGH 3.0 mm\u003c\/strong\u003e for thicker tissue. Base selection on measured sulcus depth and desired margin position.\u003c\/p\u003e\n\u003ch3 data-start=\"422\" data-end=\"485\"\u003eIs this for screw-retained or cement-retained restorations?\u003c\/h3\u003e\n\u003cp data-start=\"486\" data-end=\"594\"\u003eCement-retained. Use appropriate temporary or definitive cement and remove excess cement per best practices.\u003c\/p\u003e\n\u003ch3 data-start=\"596\" data-end=\"636\"\u003eWhat torque and driver should I use?\u003c\/h3\u003e\n\u003cp data-start=\"637\" data-end=\"736\"\u003eUse the prosthetic screw torque and driver specified in the implant system IFU. Do not over-torque.\u003c\/p\u003e\n\u003ch3 data-start=\"738\" data-end=\"774\"\u003eCan it be sterilized and reused?\u003c\/h3\u003e\n\u003cp data-start=\"775\" data-end=\"942\"\u003eFollow the label\/IFU. If supplied non-sterile, clean and steam-sterilize before use. Abutments are single-patient use; replace the prosthetic screw if worn or damaged.\u003c\/p\u003e","brand":"Surcam","offers":[{"title":"15°Deg \/ 1.5 mm","offer_id":39965071016001,"sku":"PA-300116","price":18.0,"currency_code":"USD","in_stock":true},{"title":"15°Deg \/ 3.0 mm","offer_id":40069444370497,"sku":"PA-300117","price":18.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0558\/0180\/6913\/files\/angular_titanium_abutment_NP_3.5_Nobel_Active_compatible.jpg?v=1757828703"},{"product_id":"straight-titanium-abutment-nobel-active-rp-4-3","title":"Straight Titanium Abutment RP 4.3 (Nobel Active® Compatible)","description":"\u003cp data-start=\"81\" data-end=\"424\"\u003eThe \u003cstrong data-start=\"85\" data-end=\"148\"\u003eStraight Titanium Abutment RP 4.3 (Nobel Active compatible)\u003c\/strong\u003e is engineered for predictable, cement-retained restorations on \u003cstrong data-start=\"212\" data-end=\"241\"\u003econical connection RP 4.3\u003c\/strong\u003e platforms. Its \u003cstrong data-start=\"257\" data-end=\"271\"\u003eActive Hex\u003c\/strong\u003e indexing supports precise orientation and anti-rotation, while the \u003cstrong data-start=\"339\" data-end=\"362\"\u003eTi-6Al-4V (Grade 5)\u003c\/strong\u003e body provides strength, biocompatibility, and stable margins.\u003c\/p\u003e\n\u003cp data-start=\"426\" data-end=\"444\"\u003e\u003cstrong data-start=\"426\" data-end=\"442\"\u003eClinical use\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"445\" data-end=\"841\"\u003e\n\u003cli data-start=\"445\" data-end=\"556\"\u003e\n\u003cp data-start=\"447\" data-end=\"556\"\u003eIndicated for single units or short-span bridges where a straight, cement-retained solution is appropriate.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"557\" data-end=\"659\"\u003e\n\u003cp data-start=\"559\" data-end=\"659\"\u003eAvailable \u003cstrong data-start=\"569\" data-end=\"608\"\u003egingival heights: 1.5 mm and 3.0 mm\u003c\/strong\u003e to match sulcus depth and soft-tissue thickness.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"660\" data-end=\"728\"\u003e\n\u003cp data-start=\"662\" data-end=\"728\"\u003eSupplied with a matched \u003cstrong data-start=\"686\" data-end=\"706\"\u003eprosthetic screw\u003c\/strong\u003e for secure seating.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"729\" data-end=\"841\"\u003e\n\u003cp data-start=\"731\" data-end=\"841\"\u003eCompatible with conventional or digital workflows (model work with analogs; CAD\/CAM for crowns as applicable).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003csection class=\"product-faqs\" aria-labelledby=\"faqs\"\u003e\n\u003carticle\u003e\n\u003ch2 data-start=\"1473\" data-end=\"1479\"\u003eFAQs\u003c\/h2\u003e\n\u003ch3 data-start=\"1480\" data-end=\"1687\"\u003e\u003cstrong data-start=\"1480\" data-end=\"1537\"\u003eIs this abutment compatible with Nobel Active RP 4.3?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-start=\"1480\" data-end=\"1687\"\u003eYes. It is designed for \u003cstrong data-start=\"1564\" data-end=\"1593\"\u003econical connection RP 4.3\u003c\/strong\u003e platforms with \u003cstrong data-start=\"1609\" data-end=\"1623\"\u003eActive Hex\u003c\/strong\u003e indexing. Always verify the platform code and index before use.\u003c\/p\u003e\n\u003ch3 data-start=\"1689\" data-end=\"1895\"\u003e\u003cstrong data-start=\"1689\" data-end=\"1734\"\u003eHow do I choose the gingival height (GH)?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-start=\"1689\" data-end=\"1895\"\u003eSelect \u003cstrong data-start=\"1744\" data-end=\"1757\"\u003eGH 1.5 mm\u003c\/strong\u003e for shallow sulcus\/thin tissue and \u003cstrong data-start=\"1793\" data-end=\"1806\"\u003eGH 3.0 mm\u003c\/strong\u003e for thicker tissue. Base selection on measured sulcus depth and desired margin position.\u003c\/p\u003e\n\u003ch3 data-start=\"1897\" data-end=\"2071\"\u003e\u003cstrong data-start=\"1897\" data-end=\"1960\"\u003eIs this for screw-retained or cement-retained restorations?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-start=\"1897\" data-end=\"2071\"\u003eCement-retained. Use appropriate temporary or definitive cement and remove excess cement per best practices.\u003c\/p\u003e\n\u003ch3 data-start=\"2073\" data-end=\"2219\"\u003e\u003cstrong data-start=\"2073\" data-end=\"2113\"\u003eWhat torque and driver should I use?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-start=\"2073\" data-end=\"2219\"\u003eUse the \u003cstrong data-start=\"2124\" data-end=\"2198\"\u003eprosthetic screw torque and driver specified in the implant system IFU\u003c\/strong\u003e. Do not over-torque.\u003c\/p\u003e\n\u003ch3 data-start=\"2221\" data-end=\"2435\"\u003e\u003cstrong data-start=\"2221\" data-end=\"2257\"\u003eCan it be sterilized and reused?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-start=\"2221\" data-end=\"2435\"\u003eFollow the label\/IFU. If supplied non-sterile, clean and \u003cstrong data-start=\"2317\" data-end=\"2336\"\u003esteam-sterilize\u003c\/strong\u003e before use. Abutments are \u003cstrong data-start=\"2363\" data-end=\"2385\"\u003esingle-patient use\u003c\/strong\u003e; replace the prosthetic screw if worn or damaged.\u003c\/p\u003e\n\u003c\/article\u003e\n\u003c\/section\u003e","brand":"Surcam","offers":[{"title":"1.5mm","offer_id":39965113876545,"sku":"PD-300098","price":15.0,"currency_code":"USD","in_stock":true},{"title":"3.0mm","offer_id":39965113909313,"sku":"PD-300114","price":15.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0558\/0180\/6913\/files\/straight_titanium_abutment_RP_4.3_Nobel_Active_compatible.jpg?v=1757598267"},{"product_id":"15-degree-angular-cement-retained-abutment-rp-4-3","title":"15° Angular Cement-Retained Abutment – RP 4.3 Platform (Nobel Active® Compatible)","description":"\u003cp data-start=\"564\" data-end=\"872\"\u003eThe \u003cstrong data-start=\"568\" data-end=\"620\"\u003e15° Angular Abutment – Regular Platform (RP 4.3)\u003c\/strong\u003e is designed for cement-retained restorations where correction of implant angulation is required. The \u003cstrong data-start=\"722\" data-end=\"746\"\u003e15-degree angulation\u003c\/strong\u003e allows clinicians to compensate for non-ideal implant positioning while maintaining a favorable prosthetic path of insertion.\u003c\/p\u003e\n\u003cp data-start=\"874\" data-end=\"1165\"\u003eManufactured from \u003cstrong data-start=\"892\" data-end=\"924\"\u003eTitanium Grade 5 (Ti-6Al-4V)\u003c\/strong\u003e, the abutment provides excellent mechanical strength, corrosion resistance, and long-term biocompatibility. Its precision-machined \u003cstrong data-start=\"1056\" data-end=\"1078\"\u003econical connection\u003c\/strong\u003e ensures stable seating and minimizes micro-movement at the implant–abutment interface.\u003c\/p\u003e\n\u003cp data-start=\"1167\" data-end=\"1462\"\u003eAvailable in \u003cstrong data-start=\"1180\" data-end=\"1221\"\u003egingival heights of 1.5 mm and 3.0 mm\u003c\/strong\u003e, the abutment supports accurate soft-tissue management and predictable emergence profile development. Supplied with a \u003cstrong data-start=\"1340\" data-end=\"1368\"\u003ematched prosthetic screw\u003c\/strong\u003e for the RP 4.3 platform, it integrates seamlessly into cement-retained restorative workflows.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli data-start=\"1469\" data-end=\"1491\"\u003e\n\u003cstrong data-start=\"1474\" data-end=\"1491\"\u003ePack Contents:\u003c\/strong\u003e1× 15° Angular Abutment – RP 4.3, 1× Matched Prosthetic Screw\u003cbr\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1590\" data-end=\"1651\"\u003e\n\u003cp data-start=\"1592\" data-end=\"1651\"\u003e\u003cstrong data-start=\"1592\" data-end=\"1616\"\u003e15° angular abutment\u003c\/strong\u003e for cement-retained restorations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1652\" data-end=\"1693\"\u003e\n\u003cp data-start=\"1654\" data-end=\"1693\"\u003ePlatform: \u003cstrong data-start=\"1664\" data-end=\"1691\"\u003eRegular Platform RP 4.3\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1694\" data-end=\"1732\"\u003e\n\u003cp data-start=\"1696\" data-end=\"1732\"\u003eConnection: \u003cstrong data-start=\"1708\" data-end=\"1730\"\u003eConical Connection\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1733\" data-end=\"1761\"\u003e\n\u003cp data-start=\"1735\" data-end=\"1761\"\u003eNobel Active® compatible\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1762\" data-end=\"1816\"\u003e\n\u003cp data-start=\"1764\" data-end=\"1816\"\u003eManufactured from \u003cstrong data-start=\"1782\" data-end=\"1814\"\u003eTitanium Grade 5 (Ti-6Al-4V)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1817\" data-end=\"1868\"\u003e\n\u003cp data-start=\"1819\" data-end=\"1868\"\u003eGingival heights available: \u003cstrong data-start=\"1847\" data-end=\"1866\"\u003e1.5 mm \/ 3.0 mm\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1869\" data-end=\"1934\"\u003e\n\u003cp data-start=\"1871\" data-end=\"1934\"\u003eCorrects implant angulation for improved prosthetic alignment\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1935\" data-end=\"1981\"\u003e\n\u003cp data-start=\"1937\" data-end=\"1981\"\u003eStable seating with reduced micro-movement\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1982\" data-end=\"2024\"\u003e\n\u003cp data-start=\"1984\" data-end=\"2024\"\u003eSupplied with matched prosthetic screw\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Surcam","offers":[{"title":"15°Deg \/ 1.5 mm","offer_id":39965117939777,"sku":"PA-300112","price":18.0,"currency_code":"USD","in_stock":true},{"title":"15°Deg \/ 3.0 mm","offer_id":40069420449857,"sku":"PA-300113","price":18.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0558\/0180\/6913\/files\/angular_titanium_abutment_RP_4.3_Nobel_Active_compatible.jpg?v=1757832088"},{"product_id":"healing-cap-regular-platform-5-0","title":"Healing Cap Ø5.0 mm – Regular Platform","description":"\u003cp data-start=\"548\" data-end=\"885\"\u003eThe \u003cstrong data-start=\"552\" data-end=\"594\"\u003eRegular Platform Healing Cap – Ø5.0 mm\u003c\/strong\u003e is designed to support proper soft-tissue healing and contouring following implant placement. Compatible with \u003cstrong data-start=\"705\" data-end=\"761\"\u003eØ5.0 mm Regular Platform conical connection implants\u003c\/strong\u003e, this healing cap helps maintain the peri-implant opening while guiding gingival tissue formation during the healing phase.\u003c\/p\u003e\n\u003cp data-start=\"887\" data-end=\"1139\"\u003eManufactured from \u003cstrong data-start=\"905\" data-end=\"937\"\u003eTitanium Grade 5 (Ti-6Al-4V)\u003c\/strong\u003e, the healing cap offers excellent biocompatibility, corrosion resistance, and mechanical stability. Its smooth, rounded profile minimizes tissue irritation and supports predictable gingival adaptation.\u003c\/p\u003e\n\u003cp data-start=\"1141\" data-end=\"1393\"\u003eAvailable in \u003cstrong data-start=\"1154\" data-end=\"1198\"\u003egingival heights of 3 mm, 5 mm, and 7 mm\u003c\/strong\u003e, the healing cap allows clinicians to select the appropriate height based on tissue thickness and clinical requirements, ensuring optimal emergence profile preparation for the final restoration.\u003c\/p\u003e\n\u003cul data-start=\"1423\" data-end=\"1856\"\u003e\n\u003cli data-start=\"1423\" data-end=\"1479\"\u003e\n\u003cp data-start=\"1425\" data-end=\"1479\"\u003eHealing cap for implant-level soft-tissue management\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1480\" data-end=\"1522\"\u003e\n\u003cp data-start=\"1482\" data-end=\"1522\"\u003ePlatform: \u003cstrong data-start=\"1492\" data-end=\"1520\"\u003eRegular Platform Ø5.0 mm\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1523\" data-end=\"1561\"\u003e\n\u003cp data-start=\"1525\" data-end=\"1561\"\u003eConnection: \u003cstrong data-start=\"1537\" data-end=\"1559\"\u003eConical Connection\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1562\" data-end=\"1616\"\u003e\n\u003cp data-start=\"1564\" data-end=\"1616\"\u003eManufactured from \u003cstrong data-start=\"1582\" data-end=\"1614\"\u003eTitanium Grade 5 (Ti-6Al-4V)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1617\" data-end=\"1671\"\u003e\n\u003cp data-start=\"1619\" data-end=\"1671\"\u003eGingival heights available: \u003cstrong data-start=\"1647\" data-end=\"1669\"\u003e3 mm \/ 5 mm \/ 7 mm\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1672\" data-end=\"1727\"\u003e\n\u003cp data-start=\"1674\" data-end=\"1727\"\u003eSupports controlled gingival healing and contouring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1728\" data-end=\"1791\"\u003e\n\u003cp data-start=\"1730\" data-end=\"1791\"\u003eSmooth surface for patient comfort and tissue compatibility\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1792\" data-end=\"1856\"\u003e\n\u003cp data-start=\"1794\" data-end=\"1856\"\u003eSuitable for single-unit and multi-unit implant restorations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Surcam","offers":[{"title":"3.0 mm","offer_id":40019543425089,"sku":"HC-300105","price":14.0,"currency_code":"USD","in_stock":true},{"title":"5.0 mm","offer_id":40019543457857,"sku":"HC-300106","price":14.0,"currency_code":"USD","in_stock":true},{"title":"7.0 mm","offer_id":40019543490625,"sku":"HC-300107","price":14.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0558\/0180\/6913\/files\/HC-300105.ALL_Shopify.jpg?v=1750084139"},{"product_id":"healing-cap-regular-platform-3-6","title":"Healing Cap Ø3.6 mm – Regular Platform","description":"\u003cp data-start=\"611\" data-end=\"970\"\u003eThe \u003cstrong data-start=\"615\" data-end=\"672\"\u003eRegular Platform Healing Cap – Ø3.6 mm (Slim Profile)\u003c\/strong\u003e is designed to support controlled soft-tissue healing and precise gingival contouring following implant placement. Compatible with \u003cstrong data-start=\"804\" data-end=\"860\"\u003eØ3.6 mm Regular Platform conical connection implants\u003c\/strong\u003e, this healing cap maintains the peri-implant opening while guiding tissue formation during the healing phase.\u003c\/p\u003e\n\u003cp data-start=\"972\" data-end=\"1242\"\u003eThe \u003cstrong data-start=\"976\" data-end=\"1001\"\u003eslim profile geometry\u003c\/strong\u003e minimizes pressure on surrounding soft tissue, making it suitable for narrow restorative spaces and areas where reduced tissue displacement is required. This design supports comfortable healing and predictable emergence profile development.\u003c\/p\u003e\n\u003cp data-start=\"1244\" data-end=\"1560\"\u003eManufactured from \u003cstrong data-start=\"1262\" data-end=\"1294\"\u003eTitanium Grade 5 (Ti-6Al-4V)\u003c\/strong\u003e, the healing cap offers excellent biocompatibility, corrosion resistance, and mechanical stability. Available in \u003cstrong data-start=\"1408\" data-end=\"1452\"\u003egingival heights of 3 mm, 5 mm, and 7 mm\u003c\/strong\u003e, it allows clinicians to select the appropriate height based on tissue thickness and clinical requirements.\u003c\/p\u003e\n\u003cul data-start=\"1590\" data-end=\"2022\"\u003e\n\u003cli data-start=\"1590\" data-end=\"1646\"\u003e\n\u003cp data-start=\"1592\" data-end=\"1646\"\u003eHealing cap for implant-level soft-tissue management\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1647\" data-end=\"1689\"\u003e\n\u003cp data-start=\"1649\" data-end=\"1689\"\u003ePlatform: \u003cstrong data-start=\"1659\" data-end=\"1687\"\u003eRegular Platform Ø3.6 mm\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1690\" data-end=\"1728\"\u003e\n\u003cp data-start=\"1692\" data-end=\"1728\"\u003eConnection: \u003cstrong data-start=\"1704\" data-end=\"1726\"\u003eConical Connection\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1729\" data-end=\"1752\"\u003e\n\u003cp data-start=\"1731\" data-end=\"1752\"\u003eSlim profile design\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1753\" data-end=\"1807\"\u003e\n\u003cp data-start=\"1755\" data-end=\"1807\"\u003eManufactured from \u003cstrong data-start=\"1773\" data-end=\"1805\"\u003eTitanium Grade 5 (Ti-6Al-4V)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1808\" data-end=\"1862\"\u003e\n\u003cp data-start=\"1810\" data-end=\"1862\"\u003eGingival heights available: \u003cstrong data-start=\"1838\" data-end=\"1860\"\u003e3 mm \/ 5 mm \/ 7 mm\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1863\" data-end=\"1918\"\u003e\n\u003cp data-start=\"1865\" data-end=\"1918\"\u003eSupports controlled gingival healing and contouring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1919\" data-end=\"1957\"\u003e\n\u003cp data-start=\"1921\" data-end=\"1957\"\u003eSmooth surface for patient comfort\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1958\" data-end=\"2022\"\u003e\n\u003cp data-start=\"1960\" data-end=\"2022\"\u003eSuitable for single-unit and multi-unit implant restorations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Surcam","offers":[{"title":"3.0 mm","offer_id":40019540181057,"sku":"HC-300034","price":14.0,"currency_code":"USD","in_stock":true},{"title":"5.0 mm","offer_id":40019540213825,"sku":"HC-300035","price":14.0,"currency_code":"USD","in_stock":true},{"title":"7.0 mm","offer_id":40019540246593,"sku":"HC-300036","price":14.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0558\/0180\/6913\/files\/HC-300034.ALL_Shopify.jpg?v=1750083395"},{"product_id":"sc-type-cortical-implant-internal-hex-2-43","title":"SC-Type Cortical Dental Implant","description":"\u003cp\u003eThe \u003cstrong data-start=\"454\" data-end=\"482\"\u003eSC-Type Cortical Implant\u003c\/strong\u003e is designed to engage the cortical plate with a \u003cstrong data-start=\"531\" data-end=\"546\"\u003e3.5 mm neck\u003c\/strong\u003e and \u003cstrong data-start=\"551\" data-end=\"583\"\u003econical core\/thread geometry\u003c\/strong\u003e for stable seating and load distribution. \u003cstrong data-start=\"626\" data-end=\"650\"\u003eCoarse macro-threads\u003c\/strong\u003e support grip in mixed bone, while an \u003cstrong data-start=\"688\" data-end=\"706\"\u003eanchoring apex\u003c\/strong\u003e assists trajectory control during insertion. The \u003cstrong data-start=\"756\" data-end=\"795\"\u003eSLA (sand-blast + double acid-etch)\u003c\/strong\u003e surface and \u003cstrong data-start=\"808\" data-end=\"832\"\u003eGrade 5 ELI titanium\u003c\/strong\u003e provide a proven foundation for predictable osseointegration.\u003cbr data-start=\"894\" data-end=\"897\"\u003e\u003cstrong data-start=\"897\" data-end=\"912\"\u003eConnection:\u003c\/strong\u003e \u003cstrong data-start=\"913\" data-end=\"937\"\u003eInternal Hex 2.43 mm\u003c\/strong\u003e (verify interface\/fit with your system).\u003c\/p\u003e\n\u003ch2 data-start=\"2176\" data-end=\"2183\"\u003eFAQs\u003c\/h2\u003e\n\u003ch3 data-start=\"2185\" data-end=\"2230\"\u003eIs the SC-Type compatible with my system?\u003c\/h3\u003e\n\u003cp data-start=\"2231\" data-end=\"2360\"\u003eDesigned for \u003cstrong data-start=\"2244\" data-end=\"2268\"\u003eInternal Hex 2.43 mm\u003c\/strong\u003e families. Always \u003cstrong data-start=\"2286\" data-end=\"2310\"\u003everify interface\/fit\u003c\/strong\u003e with your specific implant system and components.\u003c\/p\u003e\n\u003ch3 data-start=\"2362\" data-end=\"2430\"\u003eWhen should I consider a cortical-profile (3.5 mm neck) implant?\u003c\/h3\u003e\n\u003cp data-start=\"2431\" data-end=\"2592\"\u003eWhen firm \u003cstrong data-start=\"2441\" data-end=\"2464\"\u003ecortical engagement\u003c\/strong\u003e is desired (e.g., limited crestal bone or need for enhanced cervical stability). Final selection is \u003cstrong data-start=\"2565\" data-end=\"2583\"\u003ecase-dependent\u003c\/strong\u003e per IFU.\u003c\/p\u003e\n\u003ch3 data-start=\"2594\" data-end=\"2644\"\u003eCan it be used for immediate or early loading?\u003c\/h3\u003e\n\u003cp data-start=\"2645\" data-end=\"2781\"\u003e\u003cstrong data-start=\"2645\" data-end=\"2666\"\u003eYes, selectively.\u003c\/strong\u003e Proceed only when \u003cstrong data-start=\"2685\" data-end=\"2725\"\u003eprimary stability (e.g., torque\/ISQ)\u003c\/strong\u003e and \u003cstrong data-start=\"2730\" data-end=\"2743\"\u003eocclusion\u003c\/strong\u003e meet the manufacturer’s IFU criteria.\u003c\/p\u003e\n\u003ch3 data-start=\"2783\" data-end=\"2836\"\u003eWhat drilling\/osteotomy protocol should I follow?\u003c\/h3\u003e\n\u003cp data-start=\"2837\" data-end=\"3013\"\u003eFollow the \u003cstrong data-start=\"2848\" data-end=\"2863\"\u003eSC-Type IFU\u003c\/strong\u003e and your surgical protocol. Cases may require \u003cstrong data-start=\"2910\" data-end=\"2940\"\u003eundersizing in softer bone\u003c\/strong\u003e or \u003cstrong data-start=\"2944\" data-end=\"2978\"\u003ecortical tapping in dense bone\u003c\/strong\u003e—do not exceed manufacturer limits.\u003c\/p\u003e\n\u003ch3 data-start=\"3015\" data-end=\"3058\"\u003eWhich restorative parts are compatible?\u003c\/h3\u003e\n\u003cp data-start=\"3059\" data-end=\"3221\"\u003eUse \u003cstrong data-start=\"3063\" data-end=\"3092\"\u003eInternal Hex 2.42\/2.43 mm\u003c\/strong\u003e compatible components (healing caps, abutments, Ti-bases, MU where indicated). \u003cstrong data-start=\"3172\" data-end=\"3209\"\u003eVerify platform code and indexing\u003c\/strong\u003e before use.\u003c\/p\u003e","brand":"Surcam","offers":[{"title":"Ø4.0 \/ 10.0 mm","offer_id":41907836944449,"sku":"SC3855INX","price":80.0,"currency_code":"USD","in_stock":true},{"title":"Ø4.0 \/ 11.5 mm","offer_id":41907837042753,"sku":"SC3868INX","price":80.0,"currency_code":"USD","in_stock":true},{"title":"Ø4.0 \/ 13.0 mm","offer_id":41907837173825,"sku":"SC3885INX","price":80.0,"currency_code":"USD","in_stock":true},{"title":"Ø4.0 \/ 16.0 mm","offer_id":41907837304897,"sku":"SC3810INX","price":80.0,"currency_code":"USD","in_stock":true},{"title":"Ø5.0 \/ 10.0 mm","offer_id":41907837370433,"sku":"SC5055INX","price":80.0,"currency_code":"USD","in_stock":true},{"title":"Ø5.0 \/ 11.5 mm","offer_id":41907837075521,"sku":"SC5068INX","price":80.0,"currency_code":"USD","in_stock":true},{"title":"Ø5.0 \/ 13.0 mm","offer_id":41907837206593,"sku":"SC5085INX","price":80.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0558\/0180\/6913\/files\/sc-type_cortical_dental_implant_internal_hex_2.43_sla.jpg?v=1758091525"},{"product_id":"compressive-dental-implant","title":"Compressive Dental Implant","description":"\u003cp\u003eThe \u003cstrong data-start=\"399\" data-end=\"429\"\u003eSurcam Compressive Implant\u003c\/strong\u003e is a \u003cstrong data-start=\"435\" data-end=\"473\"\u003eone-piece, immediate-load–oriented\u003c\/strong\u003e design for cases with limited ridge width and the need for conservative preparation. Its \u003cstrong data-start=\"563\" data-end=\"609\"\u003ecompressive, bone-condensing macrogeometry\u003c\/strong\u003e minimizes drilling and gently compacts cancellous bone to enhance primary stability. A \u003cstrong data-start=\"697\" data-end=\"726\"\u003ebendable neck (up to 30°)\u003c\/strong\u003e allows chairside correction of angulation for restorative alignment. The \u003cstrong data-start=\"800\" data-end=\"829\"\u003ealuminum-free SLA surface\u003c\/strong\u003e (dry alumina blasting + double acid etch) supports clean, predictable osseointegration. Designed for straightforward workflows, it helps clinicians achieve secure, long-lasting restorations with simplified instrumentation.\u003cbr data-start=\"1052\" data-end=\"1055\"\u003e\u003cstrong data-start=\"1055\" data-end=\"1070\"\u003eConnection:\u003c\/strong\u003e One-piece (no internal connection); restore per your prosthetic protocol.\u003c\/p\u003e\n\u003ch2 data-start=\"2742\" data-end=\"2749\"\u003eFAQs\u003c\/h2\u003e\n\u003ch3 data-start=\"2751\" data-end=\"2798\"\u003eIs this implant suitable for narrow ridges?\u003c\/h3\u003e\n\u003cp data-start=\"2799\" data-end=\"2997\"\u003eYes. The \u003cstrong data-start=\"2808\" data-end=\"2832\"\u003ecompressive geometry\u003c\/strong\u003e is intended for \u003cstrong data-start=\"2849\" data-end=\"2877\"\u003econservative osteotomies\u003c\/strong\u003e and \u003cstrong data-start=\"2882\" data-end=\"2901\"\u003eridge narrowing\u003c\/strong\u003e, enhancing primary stability via bone condensation. Final indication is case-dependent per IFU.\u003c\/p\u003e\n\u003ch3 data-start=\"2999\" data-end=\"3049\"\u003eCan I immediately load this one-piece implant?\u003c\/h3\u003e\n\u003cp data-start=\"3050\" data-end=\"3204\"\u003e\u003cstrong data-start=\"3050\" data-end=\"3076\"\u003eWhen criteria are met.\u003c\/strong\u003e Proceed with immediate\/early loading only if \u003cstrong data-start=\"3122\" data-end=\"3162\"\u003eprimary stability (e.g., torque\/ISQ)\u003c\/strong\u003e and \u003cstrong data-start=\"3167\" data-end=\"3187\"\u003eocclusal control\u003c\/strong\u003e satisfy the IFU.\u003c\/p\u003e\n\u003ch3 data-start=\"3206\" data-end=\"3247\"\u003eHow much can I bend the neck and how?\u003c\/h3\u003e\n\u003cp data-start=\"3248\" data-end=\"3367\"\u003eUp to \u003cstrong data-start=\"3254\" data-end=\"3261\"\u003e30°\u003c\/strong\u003e using the \u003cstrong data-start=\"3272\" data-end=\"3301\"\u003erecommended bending tools\u003c\/strong\u003e. Avoid repeated bends and do not exceed limits stated in the IFU.\u003c\/p\u003e\n\u003ch3 data-start=\"3369\" data-end=\"3429\"\u003eWhat prosthetic workflow is used for one-piece implants?\u003c\/h3\u003e\n\u003cp data-start=\"3430\" data-end=\"3604\"\u003eOne-piece designs are typically finished as \u003cstrong data-start=\"3474\" data-end=\"3506\"\u003eprep-and-cement restorations\u003c\/strong\u003e (or other indicated prostheses). Follow your restorative protocol and cementation best practices.\u003c\/p\u003e\n\u003ch3 data-start=\"3606\" data-end=\"3649\"\u003eWhat drilling protocol should I follow?\u003c\/h3\u003e\n\u003cp data-start=\"3650\" data-end=\"3832\"\u003eUse a \u003cstrong data-start=\"3656\" data-end=\"3685\"\u003eminimal\/under-preparation\u003c\/strong\u003e sequence to promote \u003cstrong data-start=\"3706\" data-end=\"3727\"\u003ebone condensation\u003c\/strong\u003e. Follow the manufacturer’s \u003cstrong data-start=\"3755\" data-end=\"3762\"\u003eIFU\u003c\/strong\u003e for speeds, irrigation, and any tapping; do not exceed torque limits.\u003c\/p\u003e","brand":"Surcam","offers":[{"title":"Ø3.0 \/ 6.0 mm","offer_id":41908334100545,"sku":"COMP3006","price":80.0,"currency_code":"USD","in_stock":true},{"title":"Ø3.0 \/ 8.0 mm","offer_id":41908334133313,"sku":"COMP3008","price":80.0,"currency_code":"USD","in_stock":true},{"title":"Ø3.0 \/ 10.0 mm","offer_id":41908334166081,"sku":"COMP3010","price":80.0,"currency_code":"USD","in_stock":true},{"title":"Ø3.0 \/ 12.0 mm","offer_id":41908334198849,"sku":"COMP3012","price":80.0,"currency_code":"USD","in_stock":true},{"title":"Ø3.0 \/ 14.0 mm","offer_id":41908334231617,"sku":"COMP3014","price":80.0,"currency_code":"USD","in_stock":true},{"title":"Ø3.5 \/ 6.0 mm","offer_id":41908334264385,"sku":"COMP3506","price":80.0,"currency_code":"USD","in_stock":true},{"title":"Ø3.5 \/ 8.0 mm","offer_id":41908334297153,"sku":"COMP3508","price":80.0,"currency_code":"USD","in_stock":true},{"title":"Ø3.5 \/ 10.0 mm","offer_id":41908316733505,"sku":"COMP3510","price":80.0,"currency_code":"USD","in_stock":true},{"title":"Ø3.5 \/ 12.0 mm","offer_id":41908316766273,"sku":"COMP3512","price":80.0,"currency_code":"USD","in_stock":true},{"title":"Ø3.5 \/ 14.0 mm","offer_id":41908316799041,"sku":"COMP3514","price":80.0,"currency_code":"USD","in_stock":true},{"title":"Ø3.5 \/ 16.0 mm","offer_id":41908316831809,"sku":"COMP3516","price":80.0,"currency_code":"USD","in_stock":true},{"title":"Ø4.0 \/ 6.0 mm","offer_id":41908334329921,"sku":"COMP4006","price":80.0,"currency_code":"USD","in_stock":true},{"title":"Ø4.0 \/ 8.0 mm","offer_id":41908334362689,"sku":"COMP4008","price":80.0,"currency_code":"USD","in_stock":true},{"title":"Ø4.0 \/ 10.0 mm","offer_id":41908316930113,"sku":"COMP4010","price":80.0,"currency_code":"USD","in_stock":true},{"title":"Ø4.0 \/ 12.0 mm","offer_id":41908316962881,"sku":"COMP4012","price":80.0,"currency_code":"USD","in_stock":true},{"title":"Ø4.0 \/ 14.0 mm","offer_id":41908316995649,"sku":"COMP4014","price":80.0,"currency_code":"USD","in_stock":true},{"title":"Ø4.0 \/ 16.0 mm","offer_id":41908317028417,"sku":"COMP4016","price":80.0,"currency_code":"USD","in_stock":true},{"title":"Ø4.0 \/ 18.0 mm","offer_id":41908317061185,"sku":"COMP4018","price":80.0,"currency_code":"USD","in_stock":true},{"title":"Ø4.0 \/ 20.0 mm","offer_id":41908317093953,"sku":"COMP4020","price":80.0,"currency_code":"USD","in_stock":true},{"title":"Ø4.5 \/ 6.0 mm","offer_id":41908334395457,"sku":"COMP4506","price":80.0,"currency_code":"USD","in_stock":true},{"title":"Ø4.5 \/ 8.0 mm","offer_id":41908334428225,"sku":"COMP4508","price":80.0,"currency_code":"USD","in_stock":true},{"title":"Ø4.5 \/ 10.0 mm","offer_id":41908334460993,"sku":"COMP4510","price":80.0,"currency_code":"USD","in_stock":true},{"title":"Ø4.5 \/ 12.0 mm","offer_id":41908334493761,"sku":"COMP4512","price":80.0,"currency_code":"USD","in_stock":true},{"title":"Ø4.5 \/ 14.0 mm","offer_id":41908334526529,"sku":"COMP4514","price":80.0,"currency_code":"USD","in_stock":true},{"title":"Ø4.5 \/ 16.0 mm","offer_id":41908334559297,"sku":"COMP4516","price":80.0,"currency_code":"USD","in_stock":true},{"title":"Ø4.5 \/ 18.0 mm","offer_id":41908334592065,"sku":"COMP4518","price":80.0,"currency_code":"USD","in_stock":true},{"title":"Ø4.5 \/ 20.0 mm","offer_id":41908334624833,"sku":"COMP4520","price":80.0,"currency_code":"USD","in_stock":true},{"title":"Ø5.0 \/ 6.0 mm","offer_id":41908334657601,"sku":"COMP5006","price":80.0,"currency_code":"USD","in_stock":true},{"title":"Ø5.0 \/ 8.0 mm","offer_id":41908334690369,"sku":"COMP5008","price":80.0,"currency_code":"USD","in_stock":true},{"title":"Ø5.0 \/ 10.0 mm","offer_id":41908317126721,"sku":"COMP5010","price":80.0,"currency_code":"USD","in_stock":true},{"title":"Ø5.0 \/ 12.0 mm","offer_id":41908317159489,"sku":"COMP5012","price":80.0,"currency_code":"USD","in_stock":true},{"title":"Ø5.0 \/ 14.0 mm","offer_id":41908317192257,"sku":"COMP5014","price":80.0,"currency_code":"USD","in_stock":true},{"title":"Ø5.0 \/ 16.0 mm","offer_id":41908317225025,"sku":"COMP5016","price":80.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0558\/0180\/6913\/files\/one-piece_compressive_dental_implant_bendable_neck.jpg?v=1758093002"},{"product_id":"all-in-one-50-implants-50-abutments-kit","title":"All-in-One Bundle: 50 Implants + 50 Abutments + Surgical Kit","description":"\u003cp data-start=\"1028\" data-end=\"1219\"\u003eThe Surcam® All-in-One Bundle delivers a complete implant solution—50 premium implants, 50 matching abutments, and one precision surgical kit—optimized for consistent, clinical performance.\u003c\/p\u003e\n\u003cp data-start=\"1221\" data-end=\"1566\"\u003eEach implant features Surcam’s macro\/micro geometry and SLA-treated surface for dependable primary stability and predictable osseointegration.\u003cbr data-start=\"1363\" data-end=\"1366\"\u003eAbutment options include straight, aesthetic, and concave designs with gingival heights from 1 mm to 4 mm, enabling cleansable, esthetic emergence for anterior, posterior, and full-arch indications.\u003c\/p\u003e\n\u003cp data-start=\"1568\" data-end=\"1849\"\u003eThe accompanying surgical kit is organized ergonomically with matched drills, depth markings, and drivers to ensure accurate, time-efficient procedures.\u003cbr data-start=\"1720\" data-end=\"1723\"\u003eClinicians can customize implant sizes and abutment distributions; Surcam confirms the final configuration before fulfillment.\u003c\/p\u003e\n\u003ch3 data-start=\"2658\" data-end=\"2672\"\u003e\u003cstrong data-start=\"2665\" data-end=\"2672\"\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-start=\"2674\" data-end=\"2838\"\u003e\u003cstrong data-start=\"2674\" data-end=\"2708\"\u003eWhat’s included in the bundle?\u003c\/strong\u003e\u003cbr data-start=\"2708\" data-end=\"2711\"\u003e50 Surcam implants, 50 matched abutments (type and GH per your selection), and one surgical kit for your chosen implant family.\u003c\/p\u003e\n\u003cp data-start=\"2840\" data-end=\"3032\"\u003e\u003cstrong data-start=\"2840\" data-end=\"2884\"\u003eCan I mix implant diameters and lengths?\u003c\/strong\u003e\u003cbr data-start=\"2884\" data-end=\"2887\"\u003eYes. Provide your preferred size distribution in Order Notes (e.g., Ø3.5 × 10 mm × 15; Ø4.2 × 11.5 mm × 20). Surcam will confirm before shipment.\u003c\/p\u003e\n\u003cp data-start=\"3034\" data-end=\"3223\"\u003e\u003cstrong data-start=\"3034\" data-end=\"3097\"\u003eCan I choose different abutment types and gingival heights?\u003c\/strong\u003e\u003cbr data-start=\"3097\" data-end=\"3100\"\u003eYes. Specify straight, concave, or aesthetic abutments and desired GH (1–4 mm); compatibility is verified prior to packing.\u003c\/p\u003e\n\u003cp data-start=\"3225\" data-end=\"3341\"\u003e\u003cstrong data-start=\"3225\" data-end=\"3258\"\u003eIs the surgical kit reusable?\u003c\/strong\u003e\u003cbr data-start=\"3258\" data-end=\"3261\"\u003eYes. Clean and sterilize per the IFU for repeated use and long-term reliability.\u003c\/p\u003e\n\u003cp data-start=\"3343\" data-end=\"3499\"\u003e\u003cstrong data-start=\"3343\" data-end=\"3390\"\u003eDoes this bundle support immediate loading?\u003c\/strong\u003e\u003cbr data-start=\"3390\" data-end=\"3393\"\u003eYes, when adequate primary stability and controlled occlusion are achieved according to clinical judgment.\u003c\/p\u003e\n\u003cp data-start=\"3501\" data-end=\"3663\"\u003e\u003cstrong data-start=\"3501\" data-end=\"3553\"\u003eIs the bundle compatible with digital workflows?\u003c\/strong\u003e\u003cbr data-start=\"3553\" data-end=\"3556\"\u003eYes. Use Surcam scan bodies, digital analogs, and Ti-bases for IOS → CAD\/CAM integration (sold separately).\u003c\/p\u003e","brand":"Surcam","offers":[{"title":"Default Title","offer_id":41978181419073,"sku":null,"price":3500.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0558\/0180\/6913\/files\/surgicalkit_shopify_50pcs_1.jpg?v=1737972117"},{"product_id":"scan-body-for-prime-multi-unit","title":"Scan Body for Prime Multi-Unit – CAD\/CAM","description":"\u003cp data-start=\"424\" data-end=\"750\"\u003eThe \u003cstrong data-start=\"428\" data-end=\"462\"\u003eScan Body for Prime Multi-Unit\u003c\/strong\u003e is a precision digital impression component designed for accurate capture of implant position, angulation, and orientation when used with the Surcam Prime Multi-Unit system. It enables reliable transfer of implant data into CAD\/CAM software for precise prosthetic design and fabrication.\u003c\/p\u003e\n\u003cp data-start=\"752\" data-end=\"1086\"\u003eManufactured from \u003cstrong data-start=\"770\" data-end=\"802\"\u003eTitanium Grade 5 (Ti-6Al-4V)\u003c\/strong\u003e, the scan body provides excellent durability, dimensional stability, and resistance to wear during repeated clinical and laboratory use. Its precision-machined geometry ensures optimal optical recognition by intraoral and laboratory scanners, supporting accurate digital impressions.\u003c\/p\u003e\n\u003cp data-start=\"1088\" data-end=\"1280\"\u003eDesigned for seamless integration into modern digital workflows, the scan body supports efficient prosthetic planning and fabrication, ensuring consistent and predictable restorative outcomes.\u003c\/p\u003e\n\u003cul data-start=\"1306\" data-end=\"1723\"\u003e\n\u003cli data-start=\"1306\" data-end=\"1354\"\u003e\n\u003cp data-start=\"1308\" data-end=\"1354\"\u003eScan body for \u003cstrong data-start=\"1322\" data-end=\"1352\"\u003ePrime Multi-Unit abutments\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1355\" data-end=\"1412\"\u003e\n\u003cp data-start=\"1357\" data-end=\"1412\"\u003eDesigned for \u003cstrong data-start=\"1370\" data-end=\"1410\"\u003eCAD\/CAM digital impression workflows\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1413\" data-end=\"1467\"\u003e\n\u003cp data-start=\"1415\" data-end=\"1467\"\u003eManufactured from \u003cstrong data-start=\"1433\" data-end=\"1465\"\u003eTitanium Grade 5 (Ti-6Al-4V)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1468\" data-end=\"1528\"\u003e\n\u003cp data-start=\"1470\" data-end=\"1528\"\u003eEnables precise implant position and angulation transfer\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1529\" data-end=\"1580\"\u003e\n\u003cp data-start=\"1531\" data-end=\"1580\"\u003eOptimized for intraoral and laboratory scanning\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1581\" data-end=\"1629\"\u003e\n\u003cp data-start=\"1583\" data-end=\"1629\"\u003eHigh precision fit and dimensional stability\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1630\" data-end=\"1678\"\u003e\n\u003cp data-start=\"1632\" data-end=\"1678\"\u003eDurable and corrosion-resistant construction\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1679\" data-end=\"1723\"\u003e\n\u003cp data-start=\"1681\" data-end=\"1723\"\u003eSuitable for clinical and laboratory use\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Surcam","offers":[{"title":"Default Title","offer_id":43577214632001,"sku":"TSU-100043B","price":20.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0558\/0180\/6913\/files\/TSU-100043B.1_Shopify.jpg?v=1771405047"}],"url":"https:\/\/surcamdental.shop\/collections\/best-sellers.oembed?page=2","provider":"Surcam","version":"1.0","type":"link"}