Skip to content
  • For licensed dental professionals
  • Ships worldwide from Israel
  • Free Express from $350
Impression & Lab

Impression Copings for Dental Implants

Precision impression copings for dental implants. Open-tray and closed-tray transfers engineered for accurate implant position transfer in analog workflows.

Internal Hex implant transfers and analogs for accurate impressions and model fabrication, ensuring precise seating and restorative alignment in dental implant workflows.

Global Shipping

Fast & reliable delivery

Clinician Support

Experts by your side

Secure Payments

100% safe & encrypted

Full Traceability

Lot-tracked components

Ordering in volume?

Talk to our team about supply for clinics, labs and distributors.

Contact Sales

Buy Impression Copings for Dental Implants Online

22 items

Selection guide

Find the Right Impression Coping

Choose the row that matches the connection you are restoring, then the tray technique. Open tray copings stay in the impression and suit multiple or angled implants. Closed tray copings stay on the implant and suit single units with good access.

1

Identify the connection

Internal hex, conical NP or RP, or a multi-unit abutment. Check the implant record.

2

Pick the tray technique

Open tray for several or divergent implants. Closed tray for a single implant with limited access.

3

Add the matching analog

Order the implant analog for the same platform so the lab can pour the model.

ConnectionOpen trayClosed tray
Internal hex, Ø3.75 platform2.42 / 2.43 mm hexShort open tray transferTMS-1001Long open tray transferTMS-1301Closed tray coping, PVD coatedTMC-0910 to 0950Concave closed tray copingTMCC-0910 to 0950Clip closed tray copingTCMC-1001 / 1501
Internal hex, Ø4.5 wide platform2.42 / 2.43 mm hexLong open tray transfer, wideTWS-1301Closed tray coping, wideTWC-0910 to 0950Clip closed tray coping, wideTCWC-1001 / 1501
Conical connection, NP 3.5Narrow platformOpen tray transfer NPTO-300037 / 300124Closed tray transfer NPTMCN-300041 / 300042
Conical connection, RP 4.3Regular platformOpen tray transfer RPTO-300123 / 300038Closed tray transfer RPTMCN-300039 / 300040
General Multi-UnitMulti-unit levelOpen tray transferTM-300068Closed tray transferTMU-130012Plastic closed tray transferWQP-130013
Prime Multi-UnitMulti-unit levelShort open tray transferTMU-1000Long open tray transferTMU-1200Closed tray transferTMU-8005Replacement plastic capWQP-0011
Wise-Lock attachmentOverdentureNot offeredClosed tray coping for Wise-LockTWC-1105

Working digitally? Use an implant scan body instead of an impression coping.

What Is an Impression Coping?

An impression coping, also referred to as an implant transfer coping, is a temporary prosthetic component used during impression taking to capture the exact three-dimensional position of a dental implant. Once connected to the implant, the coping transfers implant depth, angulation, and rotational orientation to the working cast, allowing the laboratory to fabricate a restoration with accurate fit and passive seating. Impression copings form a critical link between surgical placement and prosthetic precision.

Open Tray vs Closed Tray Impression Copings

Open Tray Impression Copings

Open tray impression copings feature an extended fixation screw that protrudes through a custom tray window. After the impression material sets, the screw is loosened and the coping remains locked inside the impression. This technique provides the highest positional accuracy and is preferred for multiple implants, non-parallel implants, and full-arch restorative cases.

Closed Tray Impression Copings

Closed tray impression copings remain attached to the implant when the impression is removed. The coping is then repositioned into the impression extraorally. This method is efficient for single-implant cases with favorable parallelism and limited interarch space while maintaining reliable accuracy when properly executed.

Clinical Indications

  • Single-tooth implant impressions
  • Multi-implant restorative cases
  • Full-arch and overdenture workflows
  • Cases requiring precise rotational indexing

Impression Copings and Implant Analogs

After impression capture, the corresponding implant analog is attached to the coping within the impression. This assembly allows the laboratory to pour a master cast that accurately reproduces the implant position. For predictable results, impression copings and analogs must be platform matched and connection specific.

Analog vs Digital Workflows

Impression copings are used exclusively in conventional analog impression techniques. For digital workflows, scan bodies are required instead. Selecting the correct transfer method ensures compatibility with laboratory processes and prevents restorative misfit.

Manufacturing and Quality Standards

Surcam impression copings are precision manufactured under controlled tolerances to ensure consistent seating, minimal rotational play, and stable fixation during impression removal. Components ship non-sterile (clean and sterilize before clinical use according to the IFU), are lot tracked, and are supplied with clear platform identification to support traceability in professional clinical workflows.

Complete Implant Impression Workflow

Accurate implant impressions depend on correct component matching throughout the restorative workflow. Impression copings function as part of a coordinated system that includes implant analogs, abutments, and prosthetic components. Selecting platform-consistent components ensures passive fit, predictable laboratory outcomes, and long-term prosthetic stability.

Related Implant Components

  • Implant Analogs: Replicate the exact implant position captured by the impression coping during laboratory fabrication. View Implant Analogs
  • Healing Abutments: Shape peri-implant soft tissue prior to impression taking and maintain access to the implant platform. Browse Healing Abutments
  • Cemented Abutments: Selected after impression capture for single-unit and cement-retained restorations. Explore Cemented Abutments
  • Multi-Unit Abutments: Used in full-arch and angled implant cases where impression copings transfer multi-unit positions. View Multi-Unit Abutments
  • Ti-Bases for CAD/CAM: Required when transitioning from analog impressions to digital prosthetic fabrication. Shop Ti-Bases
  • Scan Bodies: Digital transfer components used for intraoral scanning workflows instead of impression copings. View Scan Bodies

Using platform-consistent components across impression, modeling, and restoration stages minimizes rotational error, improves prosthetic accuracy, and reduces chairside adjustments.

Zimmer Biomet®, Straumann®, Nobel Biocare®, BioHorizons® and other marks are owned by their respective holders. Surcam supplies compatible components only.

Surcam impression copings are precision transfer components used to accurately replicate the three-dimensional position of a dental implant from the patient’s mouth to the laboratory model. Each impression coping engages the implant connection with controlled tolerances, ensuring that implant depth, angulation, and rotational orientation are transferred without distortion. Available in open tray and closed tray designs, Surcam impression copings support predictable analog workflows for single-unit, multi-unit, and full-arch implant restorations.

How Do Impression Copings Work?

An impression coping screws into the dental implant and acts as a transfer device during impression taking. When the impression is removed, the coping preserves the implant’s exact position so the laboratory can fabricate a crown or bridge that fits accurately and seats passively.

When Should Open Tray Impression Copings Be Used?

Open tray impression copings are recommended for multiple implants, non-parallel implants, and full-arch cases where maximum positional accuracy is required. They minimize distortion and rotational error during impression removal. For a full comparison, read Open vs Closed Tray Impression Copings: When to Use Each.

Order the matching parts

Pair each impression coping with an implant analog for the same platform. For digital impressions, use an implant scan body instead.

Frequently Asked Questions

Impression Coping FAQs

What is an impression coping?

An impression coping (implant transfer coping) is a temporary component that connects to a dental implant during impression taking to transfer the implant’s exact position, depth, and orientation to a working cast for accurate laboratory fabrication.

What is the difference between open tray and closed tray impression copings?

Open tray impression copings use a long screw that protrudes through a tray window so the coping remains captured in the impression for maximum accuracy. Closed tray copings remain on the implant when the impression is removed and are repositioned into the impression extraorally, typically used for single implants with favorable parallelism.

When should I use an open tray impression coping?

Open tray copings are preferred for multiple implants, non-parallel implants, and full-arch cases where maximum positional accuracy and reduced transfer error are critical.

When should I use a closed tray impression coping?

Closed tray copings are commonly used for single-implant impressions with good implant parallelism and limited interarch space. They can be efficient when proper technique and component matching are maintained.

Do impression copings work with digital impressions?

No. Impression copings are for conventional analog impressions. Digital workflows require scan bodies to transfer implant position during intraoral scanning.

How do implant analogs relate to impression copings?

After the impression is taken, an implant analog is attached to the coping in the impression. This allows the laboratory to pour a master cast that reproduces the implant position for accurate restoration fabrication.

How do I choose the correct impression coping for my implant system?

Selection is connection-driven. The impression coping must match the implant connection and platform. For predictable results, use platform-matched components across the workflow, including analogs and prosthetic parts.

Are Surcam impression copings sterile and traceable?

No. Surcam impression copings ship non-sterile; clean and sterilize them before use according to the IFU. They are lot tracked and platform identified to support traceability and documentation in professional clinical workflows.

Which collections are commonly used alongside impression copings in an internal hex workflow?

Common supporting components include implant analogs and transfers, healing abutments, cemented abutments, multi-unit abutments, Ti-bases for CAD/CAM, and scan bodies. Use platform-consistent parts to reduce rotational error and minimize chairside adjustment.

Are these OEM brand components?

No. Surcam supplies compatible components only. Zimmer Biomet®, Straumann®, Nobel Biocare®, BioHorizons® and other marks are owned by their respective holders.

Guided selection

Find the right implant components in 4 steps.

1Workflow
2Connection
3Procedure
4Components
About 30 seconds

Need Support?

Our clinical support team is here to help with product, order and case inquiries.

Contact Support →

Clinics, Labs & Distributors

Supply programs for clinics, labs and authorised distributors.

Talk to sales →

Get the Right Implants, Right on Time

Order online with confidence — from single cases to bulk supply. Our team is here to help you select the right components and get them delivered fast.

Add Special instructions for your order
Coupon Code