Skip to content
Black Friday Spend $3,000+, get $1,000 in store credit. Stacks with volume pricing.$1,000 credit on $3,000+ Ends in Shop now
  • For licensed dental professionals
  • Ships worldwide from Israel
  • Free Express from $350
Closed tray transfer for Surcam Prime Multi-Unit with Prime Coating, IH 2.42

Impression CopingInternal Hexagon

Closed Tray Transfer For Prime Multi-Unit

Connection
Internal Hexagon
SKU
TMU-8005
$18each
Fits
Internal Hexagon

Compatible systems: Alpha-Bio®, BioHorizons®, Implant Direct®, MIS®, Zimmer Biomet®

Quantity

1
    $0

    Internal Hex 2.43 pathway

    From placement to restoration, one connection

    Every part below shares the Internal Hex 2.43 connection.

    1. 1Place
      Implants 10 parts · from $70(opens in a new tab)
    2. 2Heal
      Healing caps 5 parts · from $14(opens in a new tab)
    3. 3Record
      Closed Tray Transfer For Prime Multi-Unit Internal Hex Transfers and Analogs You are here
    4. 4Restore
      Cemented abutments 21 parts · from $15Straight and angled(opens in a new tab)
    5. 5Digital
      Ti-Base CAD/CAM 8 parts · from $20Scan bodies and Ti-bases(opens in a new tab)
    6. 6Full arch
      Multi-unit 17 parts · from $15Straight, 17°, 30°, 45°(opens in a new tab)

    Overview

    Prime-coated closed-tray impression coping for Surcam Prime Multi-Unit on IH 2.42 - short, accurate, easy pickup

    The Surcam Closed Tray Transfer for Prime Multi-Unit is a closed-tray (transfer) impression coping engineered for the Surcam Prime Multi-Unit system mounted on Internal Hex 2.42 mm implants. Precision-machined in Titanium Grade 5 (Ti-6Al-4V) with a smooth Prime Coating at the transmucosal zone, it delivers reliable seating, easy removal, and accurate transfer of implant/MU position into the working model.
    Includes: 1× Closed Tray Transfer (Prime Coating), 1× Plastic piece for closed-tray pickup, 1× Screw.


    Benefits

    • Accurate Closed-Tray Impressions – Transfers precise MU position and angulation without an open-tray window.

    • Prime-Coated Collar – Smooth, durable finish designed to aid tissue friendliness and cleansability during impressioning.

    • Chairside Efficiency – Ideal when interocclusal space is limited or tray access is restricted.

    • Stable Seating – Tight tolerances help minimize micromovement during impression removal.

    • System-Matched – Built for Surcam Prime Multi-Unit workflows on IH 2.42 platforms.


    Product Details

    • System: Surcam Prime Multi-Unit (brand compatibility)

    • Underlying Implant Connection: Internal Hexagon 2.42 mm

    • Material: Titanium Grade 5 (Ti-6Al-4V) transfer with Prime Coating; plastic pickup component included

    • Technique: Closed-tray (transfer) impression

    • Pack Contents:

      • 1× Closed Tray Transfer (Prime Coating) — IMTSP-01A

      • 1× Plastic for Closed Tray Transfer — WQP-0011

      • 1× Screw (inside)


    Specifications

    • Use Case: Single, segmental, and full-arch MU impressions where open-tray access is limited

    • Impression Materials: High-accuracy PVS or polyether per IFU

    • Seating/Indexing: Verify full seating and rotational index; radiograph when indicated

    • Tightening: Hand-tighten per system IFU; do not exceed manufacturer torque

    • Disinfection/Sterilization: Follow clinic protocol and component IFUs


    Why Choose Surcam Prime MU Transfers?

    • Predictable, repeatable fit and indexing in Prime MU workflows

    • Prime-coated smooth collar to support tissue-friendly handling

    • Efficient closed-tray solution for tight spaces and routine impressions


    Surcam Prime MU Transfers FAQs

    Which systems is this compatible with?

    Designed for the Surcam Prime Multi-Unit system on Internal Hex 2.42 mm implants. Use only with matching Prime MU components and verify interface fit.

    When should I choose a closed-tray transfer over open-tray?

    Use closed-tray when interocclusal space is limited, access is restricted, or you prefer a simpler tray without a screw-access window—while maintaining impression accuracy.

    What is the Prime Coating and why is it helpful?

    Prime Coating provides a smooth, durable finish on the transmucosal zone to aid tissue friendliness and cleansability during impression seating/removal.

    How is it used clinically?

    Seat and hand-tighten the transfer, confirm full seating and indexing, load the tray with PVS/polyether, take the impression, remove the tray, and then transfer the coping into the impression for model work as per protocol.

    What’s included in the package?

    IMTSP-01A (closed tray transfer with Prime Coating), WQP-0011 (plastic for closed-tray pickup), and 1× screw.

    Do I need a special tray?

    A rigid custom tray is recommended for accuracy; ensure proper relief and material thickness per impression material IFU.

    Technical sheets

    Catalog pages, size charts and drilling protocols

    Open in new tab ↗

    Reviews

    Recently viewed

    Add Special instructions for your order
    Coupon Code