Skip to content
Black Friday Spend $3,000+, get $1,000 in store credit. Stacks with volume pricing.$1,000 credit on $3,000+ Ends in Shop now
  • For licensed dental professionals
  • Ships worldwide from Israel
  • Free Express from $350
S.O.S Screw Out Set broken implant screw removal kit: SOS drill, SOS climb drill, drill guide and screw holder

ToolInternal Hexagon

S.O.S Screw Out Set – Broken Implant Screw Removal Kit

Broken implant screw removal kit: a drill guide that seats in the implant hex and reverse SOS drills that back out a screw fractured below the implant top. Supplied non-sterile.

Connection
Internal Hexagon
SKU
SOS-SET
Material
stainless steel
$200each
Fits
Internal Hexagon

Quantity

1
    $0

    Overview

    The Surcam S.O.S Screw Out Set is a broken implant screw removal kit for the situation every restorative dentist dreads: an abutment or prosthetic screw that has fractured below the top of the implant. The set guides a dedicated reverse drill onto the broken fragment so it can be backed out of the implant.

    What's in the set

    • SOS drill (SCD-171)
    • SOS climb drill (SCD-172)
    • SOS drill guide (SG-172)
    • Orientation lead screw holder (OLCH-2000)

    How it works

    1. Confirm the broken screw sits below the occlusal surface of the implant.
    2. Seat the SOS drill guide (SG-172) in the implant hex.
    3. Run the SOS drill through the guide in the contra-angle, counter-clockwise, at 65 to 80 RPM. Use a light tapping action, similar to tapping with a hammer, rather than steady pressure.
    4. Take the broken screw out.

    Before use

    The instruments are stainless steel and are supplied non-sterile. Inspect them for deformation, breakage or corrosion before each use, then clean and sterilize them as described in the IFU. Avoid excessive pressure, which can break the working edges. For screws with a damaged head that still sit above the implant, see the Corkskey extractor and the other implant screw removal tools.

    Specifications

    ContentsSCD-171, SCD-172, SG-172, OLCH-2000
    Useabutment or prosthetic screw broken below the implant top
    Connectionguide seats in the implant hex
    Drill speed65–80 RPM, counter-clockwise
    Materialstainless steel
    Supplied non-sterile

    Verify platform and indexing against your system before use. Follow the IFU for torque and loading.

    Technical sheets

    Catalog pages, size charts and drilling protocols

    FAQ

    Questions about S.O.S Screw Out Set – Broken Implant Screw Removal Kit

    All FAQs →
    How do you remove a broken abutment screw from an implant?

    Seat the SOS drill guide in the implant hex, then run the SOS drill through the guide counter-clockwise at 65 to 80 RPM with a light tapping action until the fragment backs out. The full steps are in the Surcam catalog and IFU.

    What is in the S.O.S Screw Out Set?

    An SOS drill (SCD-171), an SOS climb drill (SCD-172), an SOS drill guide (SG-172) and an orientation lead screw holder (OLCH-2000).

    Which implants does the S.O.S set work with?

    The guide seats in the implant hex, and the set is listed with the Surcam internal hex line. Check your implant connection before use.

    What speed should the SOS drill run at?

    65 to 80 RPM, counter-clockwise, in the contra-angle. Use a tapping action rather than steady pressure.

    Is the set supplied sterile?

    No. The instruments are supplied non-sterile. Inspect, clean and sterilize them before each use as described in the IFU.